Cooper Lighting 2VRGC Folheto

Página de 1
FAIL-SAFE
®
ARCHITECTURAL V
ANDAL RESIST
ANT
COOPER LIGHTING
D E S C R I P T I O N
The Fail-Safe VRGC and 2VRGC
Series fluorescent luminaires
feature recessed aesthetics and
the latest in energy-efficient
technology. Their Energy
Saving Ballast complies with
Federal Energy Standards.
Features include a die-
embossed housing, four
convenient end suspension
points, and high comfort
photometrics. U.L. listed and
C.S.A. certified.
•  Nominal 41/2" deep
paracontoured housing,
die formed code gauge,
prime cold rolled steel
•  Finish is lighting grade
baked white enamel
•  Die formed, heavy gauge,
flat steel door with
reinforced mitered corners
and baked white enamel
finish. Positive light seals.
Frame and lens are secured
to housing with 4 or 6
stainless steel TORX
®
screws
•  Positive cam action spring
loaded steel latches with
baked white enamel finish
•  Ballasts are CBM/ETL Class
"P" and positively secured
by mounting bolts.
Pressure lock lampholders
VRGC
2VRGC
1 '   x   4 ' ,   2 '   x   2 ' ,   2 '   x   4 '
1 ,   2 ,   3 ,   O R   4   L A M P
V A N D A L   R E S I S T A N T
L U M I N A I R E
M O U N T I N G
A
B
C
C
B
B
A
B
C
VRGC
5 5/8"
11 3/4"
48" 
(1' x 4')
(143mm)
(298mm)
(1219mm)
2VRGC
4 5/8"
23 3/4"
24"
(2' x 2')
(117mm)
(603mm)
(610mm)
2VRGC
4 5/8"
23 3/4”
48"
(2' x 4')
(117mm)
(603mm)
(1219mm)
D I M E N S I O N S
O R D E R I N G   I N F O R M AT I O N
S A M P L E   N U M B E R :   2 V R G C - 2 3 2 A - 1 2 0 V - E B 8 1 - U
Options
(order as suffix)
PAF=Painted After
Fabrication
GL=Internal Single
Element Fusing
GM=Dual Element
Fusing
LCWE=F40/Cool White
Energy Saving Lamps,
Installed
L8730=F32T8 3000
Kelvin Lamps, Installed
L8735=F32T8 3500
Kelvin Lamps, Installed
L8741=F32T8 4100
Kelvin Lamps, Installed
EL4=Emergency
Lighting self-contained 
1
RIF1=Radio Interference
Suppressor
FR=Suitable for Fire
Rated Applications
EQ=T-BAR Safety
Earthquake Clips
3
RLS=Rotor-Lock Socket 
(T8 Lamps Only)
6S=Six TORX-head
Screws(3 per side)
SC=Safety Chain
Number of Lamps
1
23, or lamps
(Not included)
Wattage (Length)
U3
=40W (24")
U6=40W (24")
U6T8=31W (24")
20=20W (24")
17=17W (24")
U1-5/8=31W
T8 (24")
BX40=40W
Biax (24")
40=40W (48")
32=32W T8 (48")
Series
C
Trim Type
1
G=Grid/Lay-in – Standard
G=Concealed T
G=Slot Grid
F=Flange Trim
MZ=Modular Trim
EMZ=Modular Trim (Extended
Swing Arm)
Door Type
Standard
=Flat White Steel Door 
(Leave Blank)
Voltage
1
120=120V
277=277V
347=347V
UNV=
Universal
Voltage
120-277V
Voltage
LTS
=Low
Trigger Start
(20 Watt)
HTS=High
Trigger Start
(20 Watt)
Ballast Type
Standard Magnetic Ballast
Leave Blank (Biax Only)
LE3
=
Energy Saving Ballast
LEOC8= Energy Saving Ballast
(T-8 Lamp Only)
EB _ _= Generic Electronic 
Ballast
No. of Ballasts
or 2
2
Lamp Size
2
=T12
8=T8
(For Specific Electronic Ballast
Specify Brand and Catalog
Number)
Lens Type
ACTF140
= .140 Thick
ACTF187= .187 Thick
PA375= .250 polycarbonate
with .125 prismatic
overlay
(standard with 6S
option)
Product Family
VR
Width
Blank=
1'
2=2'
N O T E : For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without notice.
1
Consult Pre Sales Technical Support.
2
Two ballast in 2 or 4 lamp require LAO (less access opening). 
3
EQ Grid Clip is recommended for all 9/16"
ceiling systems.
1430