6 3/4” Aperture Step Baffle Wall Washer Low Profile Reflector Trim
LIgHTINg dATA
ExAMPLE: Multiple units with 2 Lt. 26W Quad Tube lamps, located
2’ from wall and 2’ on center, illumination on the wall 3’ down from
the ceiling is 31 f.c. beneath and 32 f.c. between fixtures.
2 LT. 26W quad Tube
1
55
53
55
41
31
41
2
43
45
43
30
29
30
3
31
32
31
31
22
21
4
21
22
21
15
15
15
5
15
15
15
10
11
10
6
11
11
11
8
8
8
7
8
8
8
6
6
6
8
6
6
6
5
5
5
9
5
5
5
4
4
4
DIST
ANCE
FROM
CEILING
, FT
.
UNITS 2 FEET FROM WALL
2’
3’
2 LT. 26W quad Tube
1
28
25
28
23
19
23
2
23
23
23
18
17
18
3
19
20
19
15
15
15
4
16
17
16
12
13
12
5
12
13
12
10
10
10
6
10
10
10
8
8
8
7
8
8
8
6
6
6
8
6
7
6
5
5
5
9
5
6
5
4
4
4
DIST
ANCE
FROM
CEILING
, FT
.
UNITS 3 FEET FROM WALL
3’
4’
FOOTCANdLES ON WALL FROM MULTIPLE UNITS
For 2 Lt. 18W Quad Tubes, multiply footcandle above by 0.7.
2 LT. 13W Twin Tube
1
27
27
27
19
16
19
2
22
22
22
16
14
16
3
17
17
17
11
11
11
4
12
12
12
8
9
8
5
9
9
9
6
6
6
6
6
6
6
5
5
5
7
4
4
4
3
3
3
8
3
3
3
3
3
3
9
2
2
2
2
2
2
DIST
ANCE
FROM
CEILING
, FT
.
UNITS 2 FEET FROM WALL
2’
3’
For 2 Lt. 13W Quad Tubes, multiply footcandle above by 0.7.
Footcandle values are averaged and rounded off and are based on a minimum of five units.
For fixture-to-wall distances, other than those shown, use maximum of 1 of 1 spacing (distance between fixtures not more than distance to wall) for best result.
Footcandle values are averaged and rounded off and are based on a minimum of five units.
For fixture-to-wall distances, other than those shown, use maximum of 1 of 1 spacing (distance between fixtures not more than distance to wall) for best result.
LIgHTINg dATA
ExAMPLE: Multiple units with 2 Lt. 13W Quad Tube lamps, located
2’ from wall and 2’ on center, illumination on the wall 3’ down from
the ceiling is 17 f.c. beneath and 17 f.c. between fixtures.
FOOTCANdLES ON WALL FROM MULTIPLE UNITS