Lightolier TU SL Series Folheto

Página de 2
0.0
45.0
90.0
FLUX
0
3896
3896
3896
5
3893
3870
3924
370
15
3785
3773
3847
1072
25
3544
3595
3723
1666
35
3187
3350
3490
2092
45
2722
2970
3211
2295
55
2179
2548
2497
2177
65
1528
1772
1745
1718
75
838
1082
876
1045
85
225
202
194
264
95
26
61
70
66
105
165
83
148
112
115
343
73
68
130
125
524
183
101
206
135
691
321
225
279
145
829
452
374
323
155
940
574
515
307
165
1015
881
752
247
175
1049
1019
1020
97
0.0
45.0
90.0
FLUX
0
3006
3006
3006
5
3001
2991
3039
286
15
2910
2936
2985
830
25
2716
2770
2829
1279
35
2442
2535
2634
1593
45
2079
2238
2477
1755
55
1659
1968
1908
1666
65
1165
1336
1315
1298
75
626
820
586
775
85
155
137
124
181
95
17
35
38
40
105
124
49
116
72
115
262
30
38
72
125
400
46
34
112
135
524
167
53
169
145
662
313
196
225
155
707
441
370
238
165
769
723
575
195
175
796
783
795
75
TU Turret Industrial Fluorescent
TU HO/VO/SL Series
Page 2 of 2
Solid Top/12% Up-Light, 48", 96" Lenghts, High Output/Slimline 2 or 3 Lamp T8
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: TU8A259SLUNVHI
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Cold Weather Ballasts (0°F)SUFFIX: CW.
Electrical Wiring Options: Consult factory.
Fluorescent Emergency Lighting Systems: Factory-installed emergency power bat-
tery pack with charger and inverter. SUFFIX: EM.
Wire Guard: 4' Wire guard available. Specify two for 96" fixtures.
Catalog Number: LFL-173.
Reflector Row Aligners: Two aligners are included with all fixtures. For additional
aligners order Catalog Number: TU-SNA.
Housing Row Couplers: 
Required to connect and stabilize continuous rows of chain
or stem-mounted fixtures. Specify one coupler per joint. Catalog Number: LFL-3
Slide Grip Hanger: 
Accepts 1/2" threaded stems or rods. Slides into fixture channel
grooves at any point along chassis. Catalog Number: LFL-111.
Canopy Spacer: 
Suspends fixture approximately 1-1/2" from surface and can be used
in conjunction with slide-grip hanger. Catalog Number: AC1 CSP
Stem and Canopy Set: 
Suspends fixture 6", 12", 18" or 24" from surface. Catalog
Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24").
Cord and Plug: 
Specify NEMA configuration and cord exit location when ordering.
For 120 volt fixtures specify: Catalog Number CPA* NEMA 5-15P. For 277 volt fix-
tures specify: CPB* NEMA.
Chain Hanger Kits: Includes two 5' heavy duty link chains with “S” hooks for fixture
suspension. Catalog Number: LFL-123
Specifications
Materials: Chassis parts are die-formed code gauge cold rolled steel, 2-5/8"
deep X 4-1/8" wide channel, grooved along the entire length for strength and
rigidity.
Reflector: Heavy duty die-formed with deep lateral embossments for additional
stability and uniformity with positive securing thumb screws for attachment to
housing.
Finish: Chassis – baked white polyester enamel. Phosphate undercoating.
Reflector – baked white polyester enamel (standard), porcelain reflector finish
(optional).
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. Listed by Underwriters Laboratories. Suitable for indoor dry
and damp locations.
This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org
TU
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
Turret Industrial:
Flat Reflector
deep channel
housing
Fixture
Length:
= 48"
= 96"
Reflector
Number of Lamps in Width:
(By Others) 2 or 3 Lamps
Lamp Types/Watts:
44HO=44W T8 380mA (48")
48HO=60W T12 800mA (48")
86HO=86W T8 380mA (96")
96HO=110W T12 800mA (96")
48VO=110W T12 1500mA (48")
96VO=215W T12 1500mA (96")
48SL=38W T12 Slimline (48")
59SL=59W T8 Slimline (96")
96SL=75W T12 Slimline (96")
Voltage:
120 or 277
UNV=120-277
Ballast Type:
1-2 Lamp T12 Magnetic VHO
PH
-
1-2 Lamp T12 Electronic HO or SL
-
SS
<
20THD
<
10THD
1-2 Lamp Elec. T8
SO*
HI*
1 & 2 Lamp Elec. T8
SO*
HI*
*Instant Start Standard
Note: For T8 UNV you must use HI Ballast code
Model No. TU8A259SL120SO
LER = FI - 85
IW - 109
BF - .85
Comparative yearly lighting energy cost per
1000 lumens = $2.82
Report Number: ITL42342
Catalog Number: TU8A259SL120SO
Lamps: F96T8
Luminaire: Fabricated metal ballast hous-
ing. White polyester painted finish.
Ballast: 22120-2T8-59
Report is based on 5800 Lumens per lamp.
Efficiency: 93.6%
CIE Type-Semi-Direct
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.3
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
96.250
12.500
CANDELA DISTRIBUTION
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 99 95 91 86 83 80 80 78 76
0
2 90 82 75 74 69 65 70 66 62
0
3 82 72 64 65 59 54 61 56 52
0
4 74 63 55 57 51 46 54 48 44
0
5 68 56 48 51 44 39 48 42 38
0
6 63 50 42 46 39 34 44 38 33
0
7 58 45 37 42 35 30 39 33 29
0
8 54 41 33 38 31 27 36 30 26
0
9 50 38 30 35 28 24 33 27 23
10 47 35 27 32 26 21 31 25 21
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
2296
20.7
22.1
0
0-
0
40
3988
34.4
36.7
0
0-
0
60
7410
63.9
68.2
0
0-
0
90
9664
83.3
89.0
90-180
000
1198
10.3
00
11.0
0
0-180
10862
93.6
100.0
ZONAL LUMEN SUMMARY
Lightolier
a Genlyte company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company
Section 7/Folio Q60-15
Reflector
White Paint
Porcelian
12% Up-Light
A
P
Solid Top
S
T
Model No. TU8A296HO120SS
LER = FI - 68
IW - 178
BF - .84
Comparative yearly lighting energy cost per
1000 lumens = $3.53
Report Number: ITL42348
Catalog Number: TU8A296HO120SS
Lamps: F96 HO ES
Luminaire: Fabricated metal ballast hous-
ing. White polyester painted finish.
Ballast: REL-2S110-RH-TP
Report is based on 8000 Lumens per lamp.
Efficiency: 90.4%
CIE Type-Semi-Direct
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.3
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
96.250
12.500
CANDELA DISTRIBUTION
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 95 91 87 82 79 76 77 74 72
0
2 86 79 72 71 66 62 66 63 59
0
3 78 69 61 62 56 52 58 53 49
0
4 72 61 52 55 49 44 52 46 40
0
5 66 54 46 49 42 37 46 40 36
0
6 62 48 40 44 37 32 41 36 31
0
7 56 44 36 40 33 29 38 32 28
0
8 52 40 32 36 30 25 34 29 25
0
9 48 36 29 33 27 23 32 26 22
10 45 33 26 31 25 20 29 24 20
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
3108
19.4
21.5
0
0-
0
40
5200
32.5
35.9
0
0-
0
60
9672
60.4
66.9
0
0-
0
90
12699
79.4
87.8
90-180
000
1767
11.0
00
12.2
0
0-180
14466
90.4
100.0
ZONAL LUMEN SUMMARY