Energos Control System 3-Light T5 per 4' (121.92cm) (Nominal) Louver
Lamp Ordering Information
Design
Lamp Type
Wattage
Rated Output
(Lumens)
Color (K)
M
T5
28
2600*
3000
N
T5
28
2600*
3500
O
T5
28
2600*
4100
P
T5
54
4450*
3000
Q
T5
54
4450*
3500
R
T5
54
4450*
4100
Ballast Ordering Information
Design
Lamp Type
Ballast Factor
Start Type
THD %
F
T5
1.00
Program
<10
G
T5HO
1.00
Program
<10
I
Dim T5
1.00 / .01
Program
<10
J
Dim T5HO
1.00 / .03
Program
<10
Lamp and Ballast System Data
Design
Lamp Type
(T8 or T5)
Ballast
Factor (BF)
Ballast
THD (%)
Lamp Rated
Wattage
Lamp
Rated
Output
Lamp
Color
Color
(Kelvin)
IES Output
(lumens)
System
Input
Watts
System
Efficacy
(lum/watt)
System
Lamp Life
(Hours)
Start
Type
FM
T5
1
<10
28
2600
3000
2600
31.0
83.87
20000
Program
FN
T5
1
<10
28
2600
3500
2600
31.0
83.87
20000
Program
FO
T5
1
<10
28
2600
4100
2600
31.0
83.87
20000
Program
GP
HO
1
<10
54
4450
3000
4450
58.5
76.07
20000
Program
GQ
HO
1
<10
54
4450
3500
4450
58.5
76.07
20000
Program
GR
HO
1
<10
54
4450
4100
4450
58.5
76.07
20000
Program
IM
T5 DIM
1.0 / .01
<10
28
2600
3000
2600 / 26
33.5 / 8
77.60
NA
Program
IN
T5 DIM
1.0 / .01
<10
28
2600
3500
2600 / 26
33.5 / 8
77.60
NA
Program
IO
T5 DIM
1.0 / .01
<10
28
2600
4100
2600 / 26
33.5 / 8
77.60
NA
Program
JP
T5HO DIM
1.0 / .03
<10
54
4450
3000
4450 / 134
63 / 12.5
70.60
NA
Program
JQ
T5HO DIM
1.0 / .03
<10
54
4450
3500
4450 / 134
63 / 12.5
70.60
NA
Program
JR
T5HO DIM
1.0 / .03
<10
54
4450
4100
4450 / 134
63 / 12.5
70.60
NA
Program
*25°C Rating
Do not alter lumen values or ballast factor light losses when completing
calculations using Energos IES files. Files have already been adjusted. The lumen
value for the lamp (within a Lighting Design program) will be the IES Ouput value
shown on this table.
calculations using Energos IES files. Files have already been adjusted. The lumen
value for the lamp (within a Lighting Design program) will be the IES Ouput value
shown on this table.
*25°C Rating
All data is per 1 lamp on a two lamp system at 277 VAC.
All data is per 1 lamp on a two lamp system at 277 VAC.
Data is based on Osram Sylvania specifications.
When ordering no lamps provided by Lightolier, use lamp code “Z”.
When ordering no lamps provided by Lightolier, use lamp code “Z”.