Lightolier GVB SERIES 1X4 Folheto

Página de 2
GUARDSMAN
GVB SERIES 1X4
Page 2 of 2
VANDAL RESISTANT, 1'x4' SURFACE BOX FLUORESCENT, 1 OR 2 LAMP, T8 
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
Section 6A/Folio P40-10
Job Information
Type:
OPTIONS & ACCESSORIES
FUSING:
Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. 
SUFFIX: RF.
ELECTRICAL/WIRING OPTIONS: Consult factory.
SPECIFICATIONS
MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud
welded for rigidity. Lens Frame (FS) flush full-size steel frame.
FINISH: Chassis exterior—white baked acrylic enamel. Cavity—white
baked acrylic enamel minimum reflectance 86%. Phosphate undercoating.
LENS: (VL) prismatic lens is 3/16" thick, pattern 12, minimum impact strength,
130 foot pounds.
ELECTRICAL: Thermally protected class "P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY
MODEL NO. GVB1SFSVL232120SO
ORDERING INFORMATION  
Explanation of Catalog Number.   Example: GVB1SFSVL232120SOGLR
GV
GUARDSMAN
VANDAL
RESISTANT 
B
BODY STYLE:
Surface Box
1
FIXTURE
WIDTH
S
CEILING
TYPE:
S=Surface
FS
LENS FRAME:
FS
= Flat Full 
Size Steel 
Frame
VL
LENS/
SHIELDING
TYPE:
VL=High Impact 
Prismatic 
Lens 
(Standard)
LAMP
QUANTITY:
(By Others)
1=1 Lamp
2=2 Lamp
LAMP/
FIXTURE
LENGTH:
32 =T8
(Normal 48")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate suffix
to catalog no., ie: (GLR)
coefficients of utilization — zonal cavity method  
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
60
58
56
55
53
52
53
51
50
2
56
52
48
49
46
44
47
45
43
3
51
46
42
44
41
38
42
40
37
4
48
42
37
40
36
33
38
35
33
5
44
38
33
36
32
29
35
32
29
6
41
34
30
33
29
26
32
28
26
7
38
31
27
30
26
23
29
26
23
8
36
29
24
28
24
21
27
24
21
9
33
26
22
26
22
19
25
22
19
10
31
25
20
24
20
18
23
20
18
visual comfort probability 
room size
ceiling height
ceiling height
W
L
8.5
10.0
13.0
16.0
8.5
10.0
13.0
16.0
20
20
69
73
78
83
70
75
80
84
20
30
62
66
70
74
62
67
73
77
20
40
58
61
66
69
59
62
68
72
20
60
55
58
62
65
54
58
62
66
30
20
69
74
78
82
70
75
80
83
30
30
62
66
70
74
62
66
72
76
30
40
57
61
65
68
57
61
66
70
30
60
54
57
60
63
53
56
60
64
30
80
52
55
55
60
52
54
56
60
40
20
70
75
79
82
71
76
80
83
40
30
63
67
71
74
63
67
72
76
40
40
58
61
65
68
57
61
65
69
40
60
54
57
59
62
53
56
59
63
40
80
52
54
56
59
52
54
55
59
40
100
52
53
54
56
51
53
53
56
60
30
64
67
71
74
64
68
72
76
60
40
59
62
65
68
58
61
65
69
60
60
54
57
58
62
54
56
58
62
60
80
52
54
55
58
52
53
54
58
60
100
52
53
53
55
51
52
52
55
100
40
62
64
66
70
61
64
67
71
100
60
57
59
60
63
57
58
59
63
100
80
55
56
56
59
54
55
55
58
100
100
54
54
53
56
53
53
53
54
room cavity ratio
luminaries lengthwise
luminaries crosswise
BALLAST TYPE:
<20THD <10THD
1 & 2 Lamp Elec T8
SO*
H
I
*
LOL Dimming T8
PS
*Instant Start Standard
Other dimming options. Consult factory.