Lightolier 9376 Folheto

Página de 2
0’
1’
2’
3’
4’
5’
0’
1’
2’
3’
4’
5’
Lighting Data 2-39W T5 High Output
1’
157
132
76
36
17
9
2’
123
106
65
32
14
6
3’
78
69
47
27
13
6
4’
51
46
34
22
13
7
5’
30
27
21
15
9
6
6’
19
18
15
11
8
5
7’
12
12
10
8
6
4
8’
8
8
7
5
4
3
9’
6
6
5
4
3
3
196
166 196
153
136 153
107
100 107
83
80
83
50
49
50
40
39
40
27
27
27
19
19
19
16
16
16
170
77 170
129
65 129
84
54
84
63
50
63
35
30
36
29
26
29
19
18
19
13
13
13
11
11
11
Footcandles on Wall
Track 3 Feet From Wall
Single Unit
Multiple  Units
4’
6’
3’
Distance From Ceiling
45˚
EXAMPLE:  With track located 4’ from wall and multiple units
spaced 6’ on center and aimed 45˚ from horizontal, the illumination
on wall 4’ from ceiling will be 57 f.c. beneath units and 48 f.c.
between units.
1’
87
75
48
24
10
3
2’
86
76
53
31
16
7
3’
65
58
43
27
15
8
4’
47
43
33
23
15
9
5’
34
32
26
19
13
9
6’
23
21
18
14
10
7
7’
16
15
13
10
8
6
8’
11
11
9
8
6
5
9’
8
8
7
6
5
4
105
97 105
117
111 117
96
93
96
79
77
79
66
64
66
47
46
47
35
35
35
29
29
29
22
22
22
92
69
92
100
82 100
80
70
80
65
60
65
54
51
54
38
37
38
29
28
29
24
24
24
18
18
18
87
48
87
92
60
92
71
53
71
57
48
57
47
42
47
33
30
33
25
23
25
21
20
21
16
15
16
Track 4 Feet From Wall
Single Unit
Multiple  Units
4’
5’
6’
4’
Distance From Ceiling 
45˚
Footcandles are average and rounded off and data for multiple units are based on a minimum of five units.
Footcandles on wall:
Beam Center
Beam Center
178 114 178
136
95 136
91
74
91
70
62
70
41
38
41
33
32
33
22
21
22
15
15
15
13
13
13
5’
0’
1’
2’
3’
4’
5’
1’
61
55
41
27
16
10
2’
62
56
43
29
18
11
3’
55
51
40
28
18
12
4’
40
38
30
22
15
10
5’
31
29
24
18
13
9
6’
24
22
19
15
12
8
7’
18
17
15
12
10
7
8’
13
12
11
9
7
6
9’
10
9
8
7
6
5
99
96
99
104
102 104
101
99 101
77
76
77
63
62
63
53
53
53
43
43
43
32
32
32
27
27
27
83
74
83
87
80
87
84
79
84
63
60
63
51
49
51
44
42
44
36
35
36
26
26
26
22
22
22
74
58
74
77
63
77
75
64
75
54
49
54
44
41
44
37
35
37
31
29
31
22
22
22
19
19
19
Track 5 Feet From Wall
Single Unit
Multiple  Units
4’
5’
6’
5’
Distance From Ceiling 
45˚
Beam Center
One Lamp, with louver,
aimed 45˚ down. 
Two Lamps, without louver,
aimed 45˚ up. 
Two Lamps, with louver,
aimed 45˚ down. 
0˚                  30˚
90˚
60˚
180˚             150˚
120˚
90˚
0˚                  30˚
90˚
60˚
Lamp Information:
2 X 39W T5 High Output
Mini Bi-Pin Fluorescent (9376)
1 x 39W T5 High Output
Mini Bi Pin Fluorescent (9377)
Lytespan
®
Track Lighting System
9376
Page 2 of 2
PowerWash™ T5 3 Foot Track Mounted 39 Watt High Output Fluorescent
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division) • B0902
Job Information
Type: