Cooper Lighting Series 75 Folheto

Página de 2
Series 75R Installation Manual, Page 1 of 2
100 Andrews Rd., Hicksville, NY 11801 • Phone: 516-470-1000 • Fax: 516-470-1077 • http://www.neoray-lighting.com
Figure 2
SPACER BLADE
CLEVIS BRACKET
JOINING PLATE
STEEL 
HOUSING
ALUMINUM
HOUSING
ALIGNER CLIPS
(SEE DETAIL “B”)
90° OUTSIDE 
CORNER
A
B
STEP 1. 
Attach housing to 
wall angle. Support 
housing to structure 
with tie-wire.
STEP 2. 
Install fixture from 
left to right, 
beginning with 
larger housing to 
smaller. Aluminum 
housing should be 
installed on right 
end  of the run.
STEP 3. 
Join fixture using 
joining plates. 
STEP 4.  
Align fixture using 
aligning clips.
STEP 1. 
Mount wall angle as shown in Figure 1.
Angles must be mounted level and true for fixtures to mount correctly
Use tie-wire (by others) to secure and level 
fixture housings to structure.
Based on field dimension pre-cut 4 ft 
aluminum housing to fit, using hand-saw.
NOTE “A”
Re-positioning clevis 
brackets may be required 
after cutting aluminum 
housings
NOTE “B”
Last housing of run is 
aluminum, to be field cut by 
installing contractor.
For packing purposes, 
aligning clips and spacer 
blades are mounted at end 
of housing as shown in 
detail “A”.
When installing housings, 
spacer blades will maintain 
a proper opening.
Prior to housing installation, 
reposition spacer blades 
and aligning clips shown in 
detail “B”.
Prior to installing shielding 
element, remove and 
discard spacer blades for all 
shielding elements except 
S72 bold baffle.
·
·
·
·
·
·
Figure 1
1/4"
FINISHED CEILING
8'(TYPICAL)
WALL ANGLE PROVIDED 
IN 8” SECTIONS 
CUT LAST SECTION TO 
FIT AVAILABLE SPACE
SERIES 75 INSTALLATION MANUAL