Cooper Lighting P4C800 Folheto

Página de 1
COOPER LIGHTING - LUMARK
®
INDUSTRIAL
538
COOPER LIGHTING
D I M E N S I O N S
• Low voltage output controls
up to 25 LumaWatt-
equipped fixtures
• Allow daisy-chaining of
multiple controllers
• Terminal block provides
input connections for one
to six passive infrared
motion sensors
• Input terminal allows use
of user-supplied dry-
contact switch. Switch
overrides motion sensors,
putting system into high
brightness mode
• Standard transformer
accepts 120V or 277V
user-configurable input.
208V, 240V, 347V and
480V are also available
• Three front panel lights
show system status:
amber indicates that the
controller is receiving
power, red indicates that
output from the controller
is at full brightness and
green indicates that 
output is at low 
brightness
• Front panel test switch 
provides same function 
as remote dry-contact
switch
• CMOS timer maintains
system in full brightness
mode for a 15 minute
warm-up period when
power is applied
• Operating temperature
2°C (35°F)—55°C (131°F)
D E S C R I P T I O N
The LumaWatt controller
accepts inputs from up to four
remote-mounted motion 
detectors and provides a 
low-voltage output capable of
controlling up to 25 fixtures.
Upon receiving a 24 volt DC
signal from an attached
motion sensor or dry contact
switch, it switches connected
fixtures from low intensity to
high, providing maximum
light when an area is occupied
and lowered energy usage
when the area is empty. 
U.L. listed and CSA certified.
CML
LUMAWATT
INDUSTRIAL HID
DIMMING
SYSTEM
C o n t r o l s   a l l   L u m a W a t t -
E q u i p p e d   L u m a r k   H I D
I n d u s t r i a l   L u m i n a i r e s
C O N T R O L   M O D U L E
8 23/32" [221mm]
2 13/32"
[61mm]
4 5/8"
[117mm]
3 3/4"
[95mm]
8 7/8" [225mm]
7 15/16" [202mm]
NOTES: 1 Products also available in non-US voltages and 50Hz for international markets. Consult your Cooper Lighting Representative for availability and ordering
information. Order separately. Specifications and dimensions are subject to change without notice.
O R D E R I N G   I N F O R M A T I O N
S A M P L E   N U M B E R :   S A M P L E   N U M B E R :   C M L - 1 2 0 / 2 7 7
Product Family
CML
=LumaWatt 
Control Module
Input Voltage
1, 2
120/277V=User-selectable 120V or 277V input voltage
208V
240V
347V
480V
LumaWatt Lamp Input Watts
Wattage
High (HW)
Low
Change (PC)
Metal Halide
1000W
1080
666
38%
400W
455
238
48%
250W
295
162
45%
175W
209
101
52%
Wattage
High (HW)
Low
Change (PC)
High Pressure Sodium
1000W
1100
616
44%
400W
465
215
54%
250W
300
151
50%
150W
196
118
40%
 –
2
  + 
 +      -      +
Control
#2
Aux.
Controller
 –
2
  + 
Output
 +      -       +
Aux.
Controller
 –
2
  + 
Dry
Contact