Tools Required Socket, 5/16" Socket, 3/4" Deep Well Socket, Electrical
wiring tools.
NOTE: these luminaires are designed for outdoor lighting 
services, and should not be used in area of limited ventilation 
or in high ambient temperature enclosures. Construction is 
suitable for down lighting only. Best results will be obtained 
if installed and maintained according to the following 
recommendations.
1. Open housing door by squeezing thumb latch towards front of 
housing. To relieve latch pressure, compress gasket by pushing 
door into housing. Once the latch is disengaged, gently swing the door
open. FIG. 1
2. Remove the door by opening it to 45° angle “half open/half closed” then
lift it off the hook shaped hinges. FIG. 2
3. Remove the electrical compartment cover.
Hard Mount Version
• Hard mount electrical covers requires captive screws “1” & “2” to be 
loosened. Grab handle and remove cover. FIG. 3a
Power Tray Version
• Power tray version requires captive screw “1” to be loosened. FIG. 3a
• Grab handle and open power tray. FIG. 3b
• To remove power tray from housing, unhook pin through gap in 
power tray. Slide off of back pin and unplug the electrical 
connection. FIG. 3c
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency 
during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest 
representative.
Tribute
Sheet 1 of 4
1/7/08
IMI-685
INSTALLATION INSTRUCTIONS
IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. 
WARNING: Risk of Fire/Electric Shock. If not qualified, consult an electrician.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.
WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly. 
Tighten all fixture components to their recommended torque values. Ensure door is properly latched.
WARNING: Risk of Fire/Electrical Shock. Upside down installation can result in overheating or accumulation of water in fixture. Install right side up.
NOTE: Specifications and dimensions subject to change without notice
Visit our web site at www.cooperlighting.com
Customer First Center  1121 Highway 74 South  Peachtree City, GA  30269  770.486.4800  FAX  770.486.4801    ADH070937
FIG. 1
Latch
FIG. 2
Lift
FIG. 3b
Open
Power
Tray
FIG. 3c
FIG. 3a
Screw “1”
Screw “2”
Handle