Cooper Lighting 701-IW Folheto

Página de 2
Catalog #
Project
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
07/20/2007 9:40:15 AM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADN070872
ORDERING INFORMATION
DESCRIPTION
The Nimbus II Wall series offers simple design and flexibility without 
sacrificing performance. Multiple lamp configurations in T8 and T5 high 
output fluorescent provide maximum flexibility for the architectural 
environment. Nimbus II creates a comfortable and uniformly balanced 
environment. All of these elements combined make the Neoray Nimbus II an 
excellent selection for private offices, open office areas, VDT workspaces, 
classrooms and corridors.
A ... Construction
Housing is one-piece, die-formed, 
cold rolled steel, forming a 7" x 
2-1/2" architectural profile. 
Perforated sections are 33% open 
with .1563" staggered hole pattern 
and opal diffuser. Standard 4'-0" 
and 8'-0" luminaire lengths 
combine for continuous runs.
B ... End Caps
Standard end caps are precision 
die-cast aluminum mechanically 
attached without exposed 
fasteners.
C ... Reflectors
Reflector is die-formed, semi-
specular anodized aluminum.
D ... Electrical
Luminaires are prewired with quick 
wire connectors and use UL list 
Class P, 265ma T8 electronic 
ballasts. Power factor of 95% with 
less than 20% THD. Fixtures and 
electrical components certified to 
UL and CUL standards.
E ... Finish
Luminaire housings are standard 
white using electrostatically 
applied acrylic powder coat paint.
Mounting
Fixture mounts directly to existing 
structure over a 2" x 4" standard 
electrical box mounted horizontally 
in the wall. Refer to installation 
section for details.
Nimbus II
701-IW
2T8
WALL-MOUNT
SEMI-INDIRECT
Light Distribution
Indirect - 95.7%
Direct - 4.3%
7" [177mm]
2-1/2"
[63mm]
A
C
E
D
END CAP 
B
5" [127mm]
2-1/2"
[64mm]
7-1/8" [181mm]
S TA N D A R D   L U M I N A I R E   L E N G T H S
M O D U L A R   R O W   C O N F I G U R AT I O N
• Standard length sections join easily to create rows. 
• Sections align with T-grid. 
• All sections prewired for through-wiring with quick connectors.
S A M P L E   N U M B E R :   7 0 1 I W - S P - 2 T 8 - 1 C - 1 - S U - WA - 2 4
1
Due to various constraints, some options may not be combined with others.
Please consult your Cooper Lighting Representative for availability. 
Series
701IW=Nimbus II
Wall Mount
701IW
Optics Up
S=Specular
S
Number of Lamps
(not included)
1=1 Lamp
2
Lamp Type
(Length)
T8=32W
(4' Unit)
T8
Number of
Circuits
1
1=1 Circuit
1
Voltage
1
1=120V
2=277V
3=347V
SU-WA= Surface/Wall 
Mount
SU-WA
Run Length
Individual or
continuous runs will
be configured with
4' and 8' sections only
(see sample catalog #)
Wiring
1
C=Standard Circuit
D=Dimming
E=Emergency/Night Light
B=Battery Pack
Optics Down
P=Perforated
P
U= Universal
2=2 Lamps
NEO-RAY