Cooper Lighting ADY071461 Manual Do Utilizador

Página de 5
(drywall) 
Removing fixture head from housing
Drywall bracket
(4x)
Pan head screw
#8-32 x3/8"
assembly
Housing 
Fixture head 
with mounting plate
Visor and Non-Visor
 
Do not
Warning
:  Before starting any work ensure 
that all sources of power are turned off.  All 
work must meet local/national codes and be 
performed by a certified electrician.  
mount fixtures vertically. 
Installation Instructions
Vault
C-Scroll
Roundel
These installation instructions are valid with the above Ametrix styles.
Sheet 1 of 5
Large, INDOOR
SRR 
(Semi-Recessed, Remote ballast)
ADY071461   REV A (ECN070344)
Pan head screws
#10-32 x5/8"
  Store fixture in safe place.
1.  Loosen all #10-32 x5/8" Pan head screws in keyhole slots 
     inside of fixture housing.  (16 1/2" & 22 1/2"  fixture sizes use 
     four(4) screws, 30 1/2 fixture sizes use six(6) screws"
2.  Slide fixture head assembly to side and remove from housing.
3.
1.
Semi-recessed fixtures shown without thermal protectors
#8-32
(4x)
Removing brackets from fixture housing
(2x)
Cover plate
Universal bracket
Hex nut
(ceiling grid)
Thermal protector
cover plate
Exploded view and part call-out
  
(ceiling grid)
Exploded view and part call-out
  
(drywall)
     all four #10-32 Hex nuts.
Pem-stud
Hex nut
#8-32
(4x)
Universal bracket
(2x)
1.  Remove universal brackets from fixture housing by removing 
1.