b)  Insert  a 
5
/
32
”  or  4  mm  Allen  wrench  into  the 
hexagonal key-way of the screw (see Figure 11), 
rotate  it  counter-clockwise  until  it  is  free  and 
extract it.
c)  Check  that  the  screw  is  clean  and  if  necessary 
remove dirt.
d)  Flip the screw (refer to Figure 12).
e)  Using  the  Allen  wrench  as  shown  in  Figure  11, 
rotate the screw clockwise until a torque of 9 inch 
lbs. WARNING! Do not over tighten the screw. 
It is recommended that you grip the wrench by 
the short side.
f)  Verify that if the conversion is from NG to LPG, 
the screw must be re-assembled with the red o-
ring visible (refer to Figure 13). If the conversion 
is from LPG to NG, the red o-ring of the screw 
must be not visible.
Figure 12: Flip valve 
screw.
g)  Re-attach  the  black  protection 
cap  that  was  removed  in  step  a 
(Figure 10).
8.  Reinstall  the  burner,  brick  panels, 
log  set,  embers,  and  glass  door. 
Also refer to S
econdary
 i
nStallation
 
-  l
og
  S
et
 
and
  e
MberS
  i
nStallation
When  re-installing  the  burner, 
ensure that the burner to pilot hood 
Figure 13: O-ring on valve screw.
relationship is similar to what is shown in Figure 14. On some units you 
will  need  to  pay  special  attention  when  installing  the  burner  that  the 
venturi adjustment rod is properly installed into the venturi adjustment 
piece welded to the burner venturi tube
9.  Reconnect the main gas line if it was disconnected and open the shut-off 
valve at the gas line to the unit.
10.  Use  a  small  brush  to  apply  a  warm  soapy  water  solution  to  all  gas 
connections (use a half dish soap and half warm water). If a gas leak 
is  present,  bubbling  will  occur.  Gas  leaks  can  be  repaired  by  using  an 
approved pipe thread sealant or approved Teflon tape. NEVER USE AN 
OPEN FLAME WHEN TESTING FOR LEAKS.
11.  Reconnect the electrical power to the unit.
Figure 11: Removing valve 
screw.
7.  Convert the SIT gas valve:
a)  Remove the black protection cap from the HI/LO knob by hand shown in Figure 10.
Figure 14. Ignitor 
assembly beside the 
burner.
12.  Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and 
operation and proper flame appearance. Also refer to S
econdary
 i
nStallation
 - l
og
 S
et
 
and
 e
MberS
 
i
nStallation
 for a flame appearance picture. 
13.  MAKE SURE that the conversion label is installed on or close to the rating label to signify that the 
unit has been converted to a different fuel type. 