Initial Installation
QUALIFIED INSTALLERS ONLY
trim can be combustible as long as the hearth extends at least 12” (305 mm) in front of the fireplace 
and  1”  (25  mm)  on  either  side  of  the  fireplace  opening.  To  install  the  face,  it  is  necessary  for  the 
bottom flange of the fireplace opening to overlap or be flush with the tile. If the total thickness of the 
protector pad, cement board, and finished tile is more than 1” (25 mm) the fireplace must be raised to 
accommodate additional thickness. NOTE: The Manor (the cast iron) face does NOT require any 
floor protection even when installed at floor level.
F
iRePLace
 s
uRRounD
:
NOTE: Any paint that is applied to the mantel or facing above the unit should be “heat resistance” or it 
may discolour.
CEMENT BOARD: The cement board can be fastened to the front of the unit with self-drilling metal 
screws. It is safe to screw to the outer border of the fireplace. Cement board for the hearth can be 
purchased at a local building material store. The board must have a k-value of 7.69 (metric version: 13 
W/m × K) and a R-value of 0.13 (metric version: 0.023 m² × K/W) or better.
TILED FINISH: Because of the amount of heat exuded by the fireplace, drywall cannot come directly 
up to the fireplace. Figure 21 shows the minimum dimensions for the cement board. Tile or other non-
combustible materials cover the cement board, but do not overlap into the fireplace opening. The total 
depth of the cement board and the finishing materials should be a minimum of 1” (25 mm) to maximum 
of 1⅜” (35 cm). The fireplace front will be installed over top of the finishing material.  
SMOOTH FINISH: The fireplace will have to be 
recessed  by  ½”  (12  mm)  and  two  (2)  layers  of 
cement board must be used if the area around the 
fireplace will be finished flush with the rest of the 
wall.
ROCK  OR  BRICK  FINISH:  If  the  face  of  the 
fireplace  is  to  be  recessed,  the  face  option 
chosen  will  determine  the  size  and  shape  of  the 
surrounding  material  (i.e.  brickwork).  Since  the 
dimensions provided on the face option instruction 
sheet are only approximations it is recommended 
that the steel template of the chosen face is used. 
See P
artS
 l
iSt
 - o
PtionS
  for the face template part 
number.
Figure 21.  Dimensions Facing Around Opening.
Figure 20.  Floor Level Hearth 
Requirements
Figure 19.  Raised Fireplace with 
Raised Hearth
If  the  unit  is  raised  less  than 
3”  (76mm)  it  is  mandatory  to 
have  a  hearth  installed  with 
a  protector  pad  (sheet  metal) 
placed  directly  on  the  floor  or 
hearth framing, with the cement 
board  (see  specs  below)  on 
top  of  it.  Tile,  or  another  non-
combustible  material  forms 
the  top  layer  of  the  hearth.  A 
decorative  trim  may  be  added 
to the edge of the hearth. The 
16