American Standard 1340.865 Manual Do Utilizador

Página de 4
M968492
9
2
4
5/16'' MIN.
MOUNTING
SURFACE
10
11
11
10
1
3
"
Push TUBING (14) ends into VALVE (4) side outlets. Insert VALVES (4)
into mounting holes from underside of ledge.
Press TEE (5) onto SPOUT SHANK (6) making certain that the O-RING (7) is
properly seated on SHANK (6). Push COUPLING (8) into TEE (5) and
attach to SPOUT SHANK (6) and tighten.
Install LOCKNUTS (1), METAL WASHERS (3) and RUBBER WASHERS (2)
onto valve shanks.
Place RUBBER RING (10) into ESCUTCHEONS (9) and thread onto valves
until snug against internal stop.
Tighten LOCKNUT (1) to secure VALVE (4) position.
Slide FERRULE (12) and COUPLING NUT (13) to outlet of VALVE (4)
and tighten COUPLING NUT (13) firmly.
Place WASHER (16) on top of VALVE ASSEMBLY (4).
VALVE ASSEMBLY (1340.825; 1340.855; 1340.865)
"=
VALVE ASSEMBLY (1340.725)
For Cold or Tempered Water Supply
COLD
12
13
7
6
8
5
5
13
12
14
4
4
16
4
14
MOUNTING
SURFACE
Thread of VALVE BODY (4) should extend at least 5/16 inch above
MOUNTING SURFACE (11). If necessary, adjust LOCKNUT (1).
10
15
15
9
Thread VALVE ACTUATORS (15) onto VALVES (4) and torque VALVE
ACTUATOR 12-15 ft. lbs, (12-20Nm).
   
HOT
8
9
2
4
5/16'' MIN.
MOUNTING
SURFACE
10
11
1
3
11
MOUNTING
SURFACE
10
COLD OR
TEMPERED
WATER
7
6
13
12
9
Connect water supply to VALVES (4) with 1/2" IPS FLEXIBLE SUPPLIES or
3/8" O.D. BULL-NOSE RISERS. Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when bending. Use
tubing cutter to cut to proper length.
1/2" IPS FLEXIBLE SUPPLIES or
3/8" O.D. BULL-NOSE RISERS
COUPLING NUT
1/2" IPS FLEXIBLE SUPPLIES or
3/8" O.D. BULL-NOSE RISER
COUPLING NUT
Valve assembly is same as two handle lavatory faucets. See above
instructions for assembly, (1340.725 Single Valve Faucet) is for Cold
or Tempered water only.
16