7.2. Command 
Details 
Command ID 
Command 
Name 
Soft Reset 
Data 
0: Reset + Automatic homing 
1: Reset only 
Return 
Value 
0: Command execution successful 
1: Command execution unsuccessful 
Explanation 
This command resets the system to the initial status after activation. 
However, the parameter values are retained. 
If a high-priority error requiring soft reset occurs (see 9-2, “Errors” for details), execute 
this command after solving the cause. 
Related 
Command 
Command ID = 2: Homing Start 
If only reset is executed, homing is necessary for a return. 
 
Command ID 
Command 
Name 
Error Clear 
Data 
Return 
Value 
0: Command execution successful 
1: Command execution unsuccessful 
Explanation 
If a low-priority error occurs (see 9-2, “Errors” for details), execute this command for a 
return. If this command is not executed, other commands cannot be accepted. The 
parameters and other set values are retained. 
 
Command ID 
Command 
Name 
Homing Start 
Data 
Return 
Value 
0: Command execution successful 
1: Command execution unsuccessful 
Explanation 
This command detects the origin. 
If the status is already SYNC after origin detection, this command executes homing to 
the origin only. 
Related 
Command 
Command ID = 0: Soft Reset 
If only soft reset is executed, origin detection is necessary.