Denon AVR-2310CI Manual Do Utilizador

Página de 78
2
ENGLISH
Get
ting Star
ted
Connections
Pla
ybac
k
Remot
e Contr
ol
Inf
or
mation
Tr
oubleshooting
Specifications
Multi-Zone
Making the Optimum Settings for the Connected Speakers Automatically (Audyssey Auto Setup)
1
Press
ui
 to  select
“Channel
Select”,
then press
.
2
Press 
ui
 to select a channel, press 
o
 
p
 to select 
the item, and then press
.
A U T O
S E T U P
A U D Y S S E Y
A U T O
S E T U P
M u l t E Q
S T E P 1
P r e p a r a t i o n
[ 1 / 6 ]
C o n n e c t
t h e
s p e a k e r s
a n d
p l a c e
t h e m
a c c o r d -
i n g
t o
t h e
r e c o m m e n d a -
a t i o n s
i n
t h e
m a n u a l .
S e t
t h e
f o l l o w i n g
i t e
m
s
i f
n e s e s s a r y .
A m p
A s s i g n
C h a n n e l
S e l e c t
A u t o
S e t u p
S t a r t
E N T E R
E n t e r
R E T U R N
C a n c e l
S k i p   u n u s e d   c h ’ s   m e a s u r e m e n t   f o r   t i m e s a v i n g .
n
  Front
A
 :  The sound is output from front speakers A when measuring 
the front speakers.
B
 :  The sound is output from front speakers B when measuring 
the front speakers.
A + B
 :  The sound is output simultaneously from front speakers A 
and B when measuring the front speakers.
See overleaf
Set the channel to be measured (Channel Select)
 (Channel Select)
•  Front
   The  front  speaker  to  be  measured  can  be  selected  ahead  of  time 
here.
•  Subwoofer, Surround Back
   If you set the channels you will not use beforehand, those channels 
will not be measured. Therefore, you can save an amount of time 
commensurate with that which would have been taken to measure 
those channels.
n
  Subwoofer, Surround Back
Measure
 : Default setting. Measure the selected channel.
Skip
 : Skip the selected channel and do not measure.
b
 
To cancel, press 
.
When “Amp Assign” is set to “Normal”, only then is “Surround Back” 
displayed.
d
 : Perform Audyssey Auto Setup
 The  Audyssey  Auto  Setup  function  detects  the  presence  of  each 
speaker and automatically calculates the speaker size, channel level, 
distance, and optimal crossover frequency setting. Audyssey MultEQ 
corrects acoustical distortions within the listening area. 
 Once started, MultEQ will play a series of test tones through each 
speaker. 
Before starting, connect and position all of your speakers.
1
Press
ui
to select “Auto Setup Start”, then press
.
2
Select
“Measure”
and then press
.
3
Once all the speakers have been detected, check the
results of detection of the connected speakers.
4
 Press
ui
to
select
“Next
1
Measurement”,  then
press
.
A U T O
S E T U P
A U D Y S S E Y
A U T O
S E T U P
M u l t E Q
S T E P 2
S p e a k e r
D e t e c t i o n
P l e a s e
p l a c e
t h e
m i c -
r o p h o n e
a t
e a r
h e i g h t
a t
m a i n
l i s t e n i n g
p o s i t i o n .
M e a s u r e
E N T E R
E n t e r
R E T U R N
C a n c e l
Te s t   T o n e   w i l l   s t a r t   f o r   m e a s u r e m e n t
[ 2 / 6 ]
STEP2 Speaker Detection
STEP3 Measurement
5
Once  the  screen  on
the  right  appears,
move
the
setup
microphone  to  the
second
position,
use
ui
 to  select
“Measure”,
then
press
.
    Measurements for the second position begin.
b
 
To  skip  this  step,  select  “Next  1  Calculation”  and  proceed  to 
STEP4 .
6
Perform Step 5 repeatedly for the 3rd, 4th, 5th, and
6th measurements.
    Once  measurements  for  the  sixth  position  are  completed, 
“Measurements finished.” is displayed.
b
   Measure at a total of six positions, including the main listening 
position and positions around it. It is possible to stop the settings 
with five positions or fewer, but for better results we recommend 
measuring at six positions.
A U T O
S E T U P
A U D Y S S E Y
A U T O
S E T U P
M u l t E Q
S T E P 3
M e a s u r e m e n t
P l e a s e
p l a c e
t h e
m i c -
r o p h o n e
a t
e a r
h e i g h t
a t
2 n d
l i s t e n i m g
p o s i t i o n .
M e a s u r e
N e x t
C a l c u l a t i o n
E N T E R
E n t e r
R E T U R N
C a n c e l
S t a r t   n e x t   m e a s u r e m e n t .   T e s t   T o n e   w i l l   s t a r t
[ 3 / 6 ]
STEP4 Calculation
7
 Once  measurements
are  finished,  use
ui
 to  select  “Next
1
Calculation”, then
press
.
    Analysis begins.
b
  Analysis  takes  several 
minutes 
to 
complete. 
The  time  required  for 
this  analysis  depends  on 
the  number  of  speakers 
connected.  The  greater 
the  number  of  speakers 
connected,  the  longer 
analysis will take.
A U T O
S E T U P
A U D Y S S E Y
A U T O
S E T U P
M u l t E Q
S T E P 3
M e a s u r e m e n t
P l e a s e
p l a c e
t h e
m i c -
r o p h o n e
a t
e a r
h e i g h t
a t
2 n d
l i s t e n i m g
p o s i t i o n .
M e a s u r e
N e x t
C a l c u l a t i o n
E N T E R
E n t e r
R E T U R N
C a n c e l
P r o c e e d   t o   S t e p   4   ( A n a l y z e )
[ 3 / 6 ]
A U T O
S E T U P
A U D Y S S E Y
A U T O
S E T U P
M u l t E Q
S T E P 4
C a l c u l a t i o n
N o w
c a l c u l a t i n g . . .
P l e a s e
w a i t .
■ ■ ■ ■ ■
2 5 %
[ 4 / 6 ]
 
 
 : Moves the cursor (Up/Down/Left/Right) 
 : Decision the setting
 : Return to previous menu
Remote control 
operation buttons
:
  Displaying the menu
  Cancel the menu
A U T O
S E T U P
A U D Y S S E Y
A U T O
S E T U P
M u l t E Q
S T E P 2
S p k r
D e t e c t
C h e c k
F r o n t
Y e s
C e n t e r
Y e s
S u b w o o f e r
Y e s
S u r r o u n d
Y e s
S . B a c k
Y e s
2 s p k r s
R e t r y
N e x t
M e a s u r e m e n t
E N T E R
E n t e r
R E T U R N
C a n c e l
G o t o   S t e p 3   ( M e a s u r e m e n t )   a f t e r   s p e a k e r   c h e c k
[ 2 / 6 ]
Set
tings