RU80e (KB2530WD)  
Type of Appliance 
 
Rinnai model number 
Operation / Installation 
Minimum/Maximum Gas Rate (Input) 
Electrical 
 
Electrical Consumption 
Ignition System 
Hot Water Capacity 
 
 
Temperature 
 
 
Temperature (without remote)  
Approved Gas Types 
Energy Factor (EF) 
Service Connections 
 
 
Isolation & Pressure Relief Valves Included 
 
Water Flow Control 
Minimum/Maximum Water Supply Pressure 
Condensing, Tankless, Temperature controlled, continuous flow, 
gas hot water system, Energy Star Qualified 
REU-KB2530WD-US 
Forced combustion; outdoor only 
15,200 - 152,000 BTU/h 
Appliance: 
 
 
AC 120 Volts - 60 Hz 
Temperature Controller:  
DC 12 Volts 
Normal:  41 w  Standby:  2 w  Anti-frost protection:  168 w 
Direct electronic ignition 
Minimum flow rate: 0.26 GPM 
Minimum activation flow rate: 0.4 GPM 
Maximum flow rate: 8.0 GPM 
98° - 120° F  (factory default)  Maximum temperature is selectable at 
120° F or at 140° F;  98° - 185° F available with the MCC-91-2 
controller for commercial and hydronic applications 
120° F (factory default) or 140° F 
Natural or Propane (ensure unit matches gas type) 
Natural Gas: 0.96  
 
Propane: 0.96 
Gas supply: 3/4 inch MNPT 
Cold water inlet: 3/4 inch MNPT 
Hot water outlet: 3/4 inch MNPT 
Heavy duty forged brass Webstone Isolator valves EXP E2, certified 
to NSF/ANSI 61-8 for potable water 
Water flow sensor, electronic water control and by-pass control  
15 - 150 PSI (50 PSI or above is recommended for maximum flow) 
© 2012 Rinnai Corporation 
RU80e SP                                      3/2012 
FLOW TABLE 
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior 
notice. Local, state, provincial and federal codes must be adhered to prior to installation. 
Water Flow (gpm) 
delta T - Temperature Rise (ºF) 
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
0
25
50
75
100
125
150