VA Series Outdoor LS Manual 
  Clearances 
from 
Appliance     
 
 
 
 
 
 
 
 
 
 
1.  Identify the installation location and confirm that 
the installation will meet all required clearances. 
2.  Securely attach the water heater to the wall using 
any of the holes in the wall installation brackets 
which are at the top and bottom of the water 
heater.  Ensure that the attachment strength is 
sufficient to support the weight.   Refer to the 
weight of the water heater in the Specifications 
section. 
  Attachment of the Water Heater   
 
 
 
 
 
 
 
 
 
 
 
 
 
wall installation 
brackets 
 
to 
Combustibles  
 
to Non-
Combustibles 
 
Top of 
Heater 
12 inches
(305 mm) 
2 inches
(51 mm) 
Back of 
Heater 
0 (zero) 0 
(zero) 
Front of 
Heater 
24 inches 
(610mm) 
 
24 inches 
(610 mm) 
Sides of 
Heater 
6 inches 
(152 mm) 
1/2 inch 
(13 mm) 
Floor/
Ground 
12 inches 
(305 mm) 
2 inches 
(51 mm) 
to side
to front
to top
to floor/ground
The clearance for servicing is 24 inches in front of the water heater