  How to Set the Temperature
   
 
 
 
 
 
 
 
 
 
 
 
 
 
While any hot water is being provided, 
the temperature setting can only be 
adjusted between 98º F and 110º F. 
NOTICE 
          DANGER 
Hot water can be dangerous, especially for infants or children, the elderly, 
or infirm.  There is hot water scald potential if the thermostat is set too high. 
Water temperatures over 125º F (52º C) can cause severe burns or 
scalding resulting in death. 
Hot water can cause first degree burns with exposure for as little as: 
3 seconds at 140º F (60º C) 
20 seconds at 130º F (54º C) 
8 minutes at 120º F (49º C) 
Test the temperature of the water before placing a child in the bath or 
shower. 
Do not leave a child or an infirm person in the bath unsupervised. 
  Temperature Controller Settings
   
 
 
 
 
 
 
 
 
 
 
 
 
This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied 
or when more than 1 tap is in use.  The water heater can deliver water at only one temperature setting at a time.  
The available temperatures for a given model are provided below. 
Model 
RL75i
 
98  100 102 104 106 108 110 115 120 
125  
130
135
140
150  
** 
160
**  
 
R98LSi 
R98LSi-ASME
 
98  100 102 104 106 108 110 115 120 125 130 135 140 
150
** 
160
** 
185
** 
Temp in Celsius  ºC 
37 
38 
39 
40 
41 
42 
43 
46 
49 
52 
54 
57   60 
66 
71 
85 
Temperature Settings Available (ºF)  
RL94i 
98  100 102 104 106 108 110 115 120 
125
130
135
140
150
** 
160
** 
185
** 
Check local codes for the maximum 
water temperature setting allowed 
when used in nursing homes, schools, 
day care centers, and all other public 
applications. 
NOTICE 
If a newly installed unit with a 
controller has not been powered for at 
least 6 hours then the temperature will 
return to the default setting of 104º F 
(40º C) if power is interrupted. 
NOTICE 
There may be a variation between the 
temperature displayed on the 
temperature controller and the 
temperature at the tap due to weather 
conditions or the length of pipe to the 
water heater. 
NOTICE 
1.  If the water heater is off, press 
the ON/OFF button to turn on. 
 
The priority can only be changed 
while no hot water is running. 
2.  Press the “Priority button” on the 
temperature controller.  The 
green Priority light will glow 
indicating that this controller is 
controlling the temperature and 
that the Rinnai water heater is 
ready to supply hot water. 
3. Press 
the 
▲ or ▼ buttons to 
obtain the desired temperature 
setting. 
 
All hot water sources are able to 
provide water at this temperature 
setting until it is changed again at 
this or another temperature 
controller. 
An older controller, MC-45, can be installed with the RL75i and RL94i by moving  switch No. 6 in the bank of 6  