Lochinvar AWP-SUB-08 Manual Do Utilizador

Página de 3
ARMOR
TM
 CONDENSING WATER HEATER PACKAGE SYSTEM
ARMOR
Condensing Water Heater
Submittal Sheet
AWP-Sub-08
JOB NAME ______________________________________________________________________
LOCATION ______________________________________________________________________
ARCH./ENGR.____________________________________________________________________
WHOLESALER __________________________________________________________________
MECH. CONTRACTOR ___________________________________________________________
MODEL NO. _____________________________________________________________________
TYPE GAS  ______________________________________________________________________
Btu/hr INPUT_____________________________________________________________________
RECOVERY RATE IN GPH_______________________________________@________°F RISE
NOTES
Standard Features
Up to 98% Thermal Efficiency
Modulating Burner with 5:1 Turndown
  > Direct-Spark Ignition
  > Low NOx Operation
  > Sealed Combustion
  > Low Gas Pressure Operation
> Vertical & Horizontal Direct-Vent 
  > PVC, CPVC or SS Venting up to 100 Feet
  > PVC/CPVC Sidewall Vent Termination
> Stainless Steel Heat Exchanger
  > All Welded Construction, Gasketless Design
  > 160 psi Working Pressure
  > ASME Construction (AW 286-800)
> Natural to L.P. Conversion Kit
> All Bronze Circulating Pump
> On/Off Switch
> Flow Switch
> ASME Temperature & Pressure Relief Valve 
(286-801)
> Temperature & Pressure Gauge (AW 501-801)
> Downstream Test Valves (AW 501-801)
> Adjustable Leveling Legs
> Tank Sensor
> Adjustable High Limit w/ Manual Reset
> Automatic Reset High Limit
> Condensate Trap
> Zero Clearances to Combustible Material
> 5 Year Limited Warranty (See Warranty for Details)
> 1 Year Parts Warranty (See Warranty for Details)
Smart System Features
SMART SYSTEM Digital Operating Control
> Multi Color Graphic LCD Display 
Built in Cascading Sequencer for up to 8 Water Heaters
  > Lead Lag
  > Efficiency Optimization
Building Management System Integration
  > Modbus Communication (Optional)
  > 0-10VDC Input to Control Modulation or Set point
  > 0-10VDC Modulation Rate Output
  > 0-10VDC Input to Enable/Disable call for heat
> Access to BMS Settings Through Graphic LCD Display
> Low Water Flow Safety Control & Indication
> Inlet & Outlet Temperature Sensors & Readout
> Flue Temperature Sensor
> Water Heater Pump Control
> Pump Delay with Freeze Protection
> Pump Exercise   
> Night Setback
> Building Recirculation loop Pump Control*
  > Night Setback of Building Recirculation Loop*
> Time Clock   
Maintenance Reminder
 > Ability to program name and number into the product
    as contact
 
High Voltage Terminal Strip
  > 120 VAC / 60 Hertz / 1 Phase Power Supply
  > Pump Control Contacts
     > Water Heater Pump Control Contacts
     > Building Recirculation Pump Control Contacts
>
 Low Voltage Terminal Strip
  > 24 VAC Auxiliary Device Relay 
  > Auxiliary Proving Switch Contacts
  > Flow Switch Contacts
  > Alarm on Any Failure Contacts
  > Runtime Contacts
  > Tank Sensor Contacts
  > Cascade Contacts
  > 0-10 VDC BMS External Control Contact
  > 0-10VDC Boiler Rate Output Contacts
  > Modbus Contacts
*Exclusive to Lochinvar
Optional Equipment
> Alarm Bell
> Condensate Neutralization Kit
> High & Low Gas Pressure Switches 
(AW 501-801)
> Concentric Vent Kit
(3” & 4” PVC/CPVC only)
> ModBus Communications
> SMART SYSTEM PC Software
> Room Air Vent Kits
> Stack Frame
Firing Control Systems
>
 M9 
Standard Construction
>
 M7 
California Code
 (AW 
286-801)
>
 M13 
CSD1 / FM / GE Gap
 (AW 
501-801)