Honeywell CT41A Manual Do Utilizador

Página de 8
CT41A HEATING/COOLING THERMOSTAT
69-0788-2
Push excess wire back into wall and plug hole with 
nonflammable insulation to prevent drafts from 
affecting thermostat operation.
Remove thermostat cover by pulling outward on right 
edge of cover until it snaps free of the thermostat 
base.
Fasten thermostat to wall or vertical outlet box with a 
screw through the top mounting hole. See Fig. 2 for 
hole location.
Place a bubble level or plumb line against the 
thermostat to find the level position. See Fig. 5. Start a 
screw in the center of the bottom mounting hole. 
(Move the temperature setting lever, if necessary, to 
uncover the mounting hole.)
Fig. 5. Level thermostat.
Recheck for level positioning and firmly tighten both 
mounting screws.
Be sure you have the current draw anticipator setting 
for your system. This is the number you wrote in the 
box in step 2 Remove Old Thermostat section. If you 
could not find the current draw for step 2, look on your 
primary control at the furnace. See Fig. 6. (The 
primary control is usually a gas valve, zone valve, or a 
relay or burner control box with the thermostat wires 
connected to it. For electric heat, add the fan relay 
current, usually 0.2A to 0.4A.)
Fig. 6. Locate your system current draw anticipator 
setting.
Set the heat anticipator indicator at the rating printed 
on the primary control. See Fig. 7.
CAUTION
Heat Anticipator Hazard.
Setting heat anticipator too low can cause 
anticipator burnout.
Set heat anticipator at recommended rating to 
avoid shorting out your valve or control and 
prevent burnout of your heat anticipator.
Fig. 7. Set heat anticipator indicator to match your 
primary control rating.
Press thermostat cover firmly onto the mounting clips. 
See Fig. 2.
M3774
.18
.2
.25
3
.5
.7
.9
BUBBLE LEVEL
PLUMB
LINE
PLUMB
BOB OR
WEIGHT
V8043E 1004 4
24V 50/60CY
.32 AMP @ 60CY
8406
 
24 Vac 50/60 Hz
0.4 AMP
30 VAC
0.2 AMP
T
F
T
F
OIL BURNER CONTROL
SHOWS
CURRENT 
DRAW
SHOWS 
VOLTAGE
RATING
M6116B
FROM MAIN
FUEL SUPPLY
SHOWS
VOLTAGE
RATING
TO
BURNER
SHOWS
ANTICIPATOR
SETTING
TYPICAL GAS VALVE
ZONE VALVE
SHOWS
VOLTAGE
RATING
SHOWS
ANTICIPATOR
SETTING
.18
.2
.25
3
.5
.7
.9
SCALEPLATE
M3784
ADJUSTABLE 
HEAT
ANTICIPATOR
SETTING LEVER