Lux Products TX1500 Manual Do Utilizador

Página de 3
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
•  The TX1500 can
be used with
most 24 volt 
gas, oil or electric
heating and air
conditioning 
systems, single-stage
heat pumps or gas
millivolt heating
systems.
It cannot be used
with 120 volt heating
systems or multistage
heat pumps. Ask your
dealer for other LUX
thermostats to 
control those
systems.
•  The TX1500 is 
programmable. There
are four
programming periods
per day. Each period
can be programmed separately.
Easy to use Lux Speed Dial
®
.
•  You can use the built-in time/temperature programs, or alter them to suit your
schedule. The TX1500 provides separate programming for weekdays, Saturday, and
Sunday — for both heating and cooling. You can override the programmed temperatures
for as little as one programming period or for an entire vacation.
•  In cool weather, when the system switch is set to HEAT, the TX1500 will maintain 
cooler “set back” room temperatures to save energy.  It will then change to warmer
“comfort” settings —  all automatically, at specified times during the day.
•  In warm weather, when the system switch is set to COOL, the TX1500 will maintain
warmer “set back” room temperatures to save energy. It will then change to cooler
“comfort” settings - all automatically, at specified times during the day.
•  A large liquid crystal display shows time, day of the week, and room and set 
temperatures. It will remind you when the filter should be changed in your blower. 
•  Temperature swing adjustment  lets you fine-tune your system for maximum 
comfort and economy. 
•  5/2 Minute Selectable Minimum Run/Off Time for Short Cycle/Compressor Protection
•  Two Energizer
®
or DURACELL
® 
“AA” alkaline batteries (not included) are used to retain your
time and temperature program and to light the display.
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA
FEATURES
I M P O R T A N T !
Thank you for your confidence in our product. To obtain the best results from
your investment, please read these instructions and acquaint yourself with your
purchase before installing your new thermostat. Then follow the installation
procedures, one step at a time.  This will save you time and minimize the chance
of damaging the thermostat and the systems it controls. These instructions may
contain information beyond that required for your particular installation. Please
save for future reference.
READ
INSTALLATION
INSTRUCTIONS
FIRST
TX1500b SERIES
SMART TEMP
®
ELECTRONIC THERMOSTAT
Complete, Easy To Read Programming And Installation Instructions Inside
The Active Program Period
Liquid Crystal 
Display
Fan Switch
System
Switch
Easy to 
follow 
instructions
Lux Speed Dial
®
Thermostat
Body
The Set Temperature
Thermostat 
Cover
Button to Light Display
HEAT
OFF
COOL
AUTO
ON
FAN
RESET
HOLD
NEXT
RUN
FILTER
SET
SUNDAY
PROGRAM
SET
SATURDAY
PROGRAM
SET
WEEKDAY
PROGRAM
SET
DAY/TIME
DOWN
UP
1500
P a t e n t s   P e n d i n g
MO
DAY
HEAT
PM
SIMPLIFIED INSTRUCTIONS
• Press UP/DOWN to set time.
TO SET PROGRAMS
• Rotate Dial to SET
WEEKDAY
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
the start tf the next period
TO SET TIME & DAY
• Rotate Dial to SET
DAY/TIME.
• Press UP to change
t d
HEAT
OFF
COOL
AUTO
ON
FAN
RESET
HOLD
NEXT
RUN
FILTER
SET
SUNDAY
PROGRAM
SET
SATURDAY
PROGRAM
SET
WEEKDAY
PROGRAM
SET
DAY/TIME
DOWN
UP
1500
P a t e n t s   P e n d i n g
MO
DAY
HEAT
PM
SIMPLIFIED INSTRUCTIONS
• Press UP/DOWN to set time.
TO SET PROGRAMS
• Rotate Dial to SET
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
TO SET TIME & DAY
• Rotate Dial to SET
DAY/TIME.
• Press UP to change
DOWN
UP
MO
DAY
HEAT
PM
Choose Heat or Cool
Set Day & Time
Installs Easily
Easy as
1–2–3
INSTALLATION AND OPERATING INSTRUCTIONS
WARNING: Use Energizer
®
or DURACELL
®
Alkaline Batteries Only
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
52017
INSTALLATION
Please read all instructions carefully
before beginning installation.
TOOLS REQUIRED
#1 Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
THERMOSTAT LOCATION
On replacement installations, mount
the new thermostat in place of the old
one unless the conditions listed below suggest otherwise. On new installations, follow
the guidelines listed below.
1. Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a
room that is used often. 
2. Do not install it where there are unusual heating conditions, such as: in direct 
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near hot water
pipes in a wall; near a stove on the other side of a wall. 
3. Do not locate in unusual cooling conditions, such as: on a wall separating an
unheated room; or in a draft from a stairwell, door, or window. 
4. Do not locate in a damp area. This can lead to corrosion that will shorten 
thermostat life.
5. Do not locate where air circulation is poor, such as: in a corner or an alcove; or
behind an open door. 
6. Do not install the unit until all construction work and painting has been completed. 
7. This thermostat does not require leveling.
C A U T I O N
To avoid electrical shock and 
to prevent damage to the
furnace, air conditioner, and 
thermostat, disconnect the power
supply before beginning work. This
can be done at the fuse box, at the
circuit breaker, or at the appliance.
OFF
REMOVING THE OLD THERMOSTAT
Switch electricity to the furnace and air conditioner OFF;
then proceed with the following steps.
2. Note the letters printed near the terminals. Attach labels
(enclosed) to each wire for identification. Remove and label
wires one at a time. Make sure the wires do not fall back inside the wall.
3. Loosen all screws on the old thermostat and remove it from the wall.
MOUNTING THE TX1500 ON THE WALL
3. Press up on the button on bottom of thermostat
and swing the body away from the base and up
to remove the body from the base.
C A U T I O N
Read instructions carefully
before removing any
wiring from existing 
thermostat. Wires must be
labeled before they are
removed. When removing
wires from their terminals,
ignore the color of the
wires since these may not
comply with the standard. 
Y
W
1. Remove cover from old
thermostat. Most are snap-on
types and simply pull off. Some
have locking screws on the
side. These must be loosened.
C
A
U
T
I
O
N
Be careful not to drop the body or disturb electronic parts. 
Leave the cover closed while the body is being removed from the base.
Y
W
R
2. Fill wall opening with
non-combustible 
insulation to prevent
drafts from affecting
the thermostat.  
Y
W
1. Strip insulation
3/8 in. (9.5mm)
from wire ends
and clean off
any corrosion.
C
A
U
T
I
O
N
• Your thermostat is a precision instrument. Please handle it with care. 
• Turn off electricity to the appliance before installing or servicing thermostat or any
part of the system. Do not turn electricity back on until work is completed. 
• Do not short (jumper) across electric terminals at control on furnace or air
conditioner to test the system. This will damage the thermostat and void your
warranty. 
• All wiring must conform to local codes and ordinances. 
• This thermostat is designed for use with 24 volt and millivolt systems. The
thermostat should be limited to a maximum of 1.0 amps; higher amperage may
cause damage to the thermostat. If you are in doubt, call your utility company.