Frost Protection: 
This unit has frost protection heaters mounted at different points to protect the water the water heater 
from freezing.  The heaters located on the hot water outlet line should have a resistance reading of 180-
207 ohms through each of these heaters.  The heater located on the heat exchanger piping should have 
a resistance reading of 156-180 ohms, and the one located in the water flow sensor valve should have a 
resistance reading of 24-28 ohms. 
 
Amp Fuses: 
This unit has two inline three-amp glass fuses.  Remove the fuse and check continuity through it.  If you 
have continuity through the fuse, it is good.  Otherwise, the fuse is blown and must be replaced.