Bradford-White Corp UTW465S60FR*N Manual Do Utilizador

Página de 52
Page 9 
Vent Tables
Venting Specifications for:
40 Gallon—40,000 BTU/hr. 
50 Gallon—40,000 BTU/hr. 
60 Gallon—42,000 BTU/hr. 
2” Diameter (5.1 cm) PVC Vent Connector Lengths 
Terminating
# of Elbows 
Maximum Straight 
Length ft (m) 
Minimum Straight 
Length ft (m) 
Through the Wall
45 (13.7) 
2 (0.6) 
Through the Wall
40 (12.2) 
2 (0.6) 
Through the Wall
35 (10.7) 
2 (0.6) 
Through the Wall
30 (9.2) 
2 (0.6) 
Through the Roof 
50 (15.2) 
7 (2.1) 
Through the Roof 
45 (13.7) 
7 (2.1) 
Through the Roof 
40 (12.2) 
7 (2.1) 
Through the Roof 
35 (10.7) 
7 (2.1) 
Through the Roof 
30 (9.2) 
7 (2.1) 
3” Diameter (7.6 cm) PVC Vent Connector Lengths 
Terminating
# of Elbows 
Maximum Straight 
Length ft (m) 
Minimum Straight 
Length ft (m) 
Through the Wall
115 (35.0) 
10 (3.1) 
Through the Wall
110 (33.5) 
10 (3.1) 
Through the Wall
105 (32.0) 
10 (3.1) 
Through the Wall
100 (30.5) 
10 (3.1) 
Through the Wall
95 (29.0) 
10 (3.1) 
Through the Roof 
120 (36.6) 
15 (4.6) 
Through the Roof 
115 (35.0) 
15 (4.6) 
Through the Roof 
110 (33.5) 
15 (4.6) 
Through the Roof 
105 (32.0) 
15 (4.6) 
Through the Roof 
100 (30.5) 
15 (4.6) 
Specifications
9