Gas Control Assembly to the Thermal Well (cont’d) 
Step 2. 
Route the wire leads back into relief opening. 
Step 3. 
Align the slots located on the thermal well flange 
with the tabs located on the back of the gas control. 
Step 4. 
Carefully push the gas control back onto the thermal well flange as far as 
possible towards the water heater.  Then, slide the gas control down to lock into posi-
tion.
Step 5. 
Install the burner assembly 
and connect the pilot and main feedlines 
to the gas control using a 7/16” and 3/4”
wrench, respectively.
Step 6. 
Reconnect the wire harnesses to the gas control. 
Step 7. 
Reconnect the gas piping to the gas control.  Re-
store the gas supply and check for gas leaks. 
Gas Control Assembly
Wire leads on 
thermal well 
Relief opening
Slots in thermal well 
Tabs on back of gas 
control
Pilot and main 
feedlines 
Wire harnesses 