Adjustment
 
23
1
.04.14 
Stitch length control eccentric
Requirement
When the needle (with maximum stitch length set), coming from TDC, is 3 mm above the 
needle plate, the crank 3 must have reached its front point of reversal. 
 
● Set the maximum stitch length.
 
● lTurn stitch length control device 1 (screws 2) according to the requirement.
Fig. 1 - 14
1
2
3
2