Installation Procedure
1.  Disconnect electrical power at the main breaker.
2.  Drain the system (if applicable).
3.  Install the pressure sensor and pressure shut-off sensor at the 
pressure tank tee downstream of the pressure tank (the pressure 
tank should be between the pressure sensor and the pump). The 
sensors have a ¼-18 National Pipe Thread (NPT) connection.
 
The pressure sensors should not be installed in an inverted 
orientation (up-side down). Make sure the pressure sensor and tank 
are not located more than 3 feet off the main piping.
4.  Install the unit to the wall using four mounting screws (not included) as 
shown in Figure 1 below. Remove the SubDrive lid by removing the eight 
lid screws.
Figure 1: Mounting Screws
Mounting Screw Locations 
(User Supplied Quantity 4)
Lid Screws (Included Quantity 8)