Manitowoc Ice Q-0420 Manual Do Utilizador

Página de 3
 
 
7. 
Use black silicone sealant to seal insulation to the base, foam insulation to foam insulation joints, and any voids where 
insulation meets or overlaps.  Add bulkhead corner insulation covers where the rear bulkhead and side panel corners meet. 
8. 
Verify no moisture is present in the suction line tubing.  If moisture is present, drain and dry the insulation and reinstall 
following step 10 instructions. 
9. 
Install armaflex insulation over the existing insulation on suction line.  Use 3/4” x 3/8” insulation on the evaporator outlet and 
inlet tubing and 2” x 3/8” on the rest of the suction line.  Use suitable glue to seal insulation airtight (do not use electrical 
tape).  Seal the ends of the insulation with wire ties.  
10. 
Remove clear vinyl tube from dump valve and brass wing adapter.  Install armaflex insulation over tube and then reinstall 
tube to dump valve and adapter.  Ensure white clamps are secure to prevent water from leaking.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
8005503 
Sheet 3 of 3 
06/22/00
 
7. Seal insulation to base with silicone sealant 
5. Align insulation slits with base ribbing 
10. Insulate drain line
4. Apply bead of silicone before applying insulation  
9. Install additional insulation on entire suction 
line