Roland Fantom-X8 Manual Do Utilizador

Página de 348
 
293
Effects List
 
note:
 
fig.MFX-note2.e_88
 
The Fantom-X’s Chorus effect unit can also be used as a stereo delay 
unit.
These settings allow you to select chorus or delay, and the 
characteristics of the selected effect type.
note:
 
fig.MFX-note2.e
About the STEP RESET function
06: STEP FILTER
16: STEP RING MODULATOR
19: STEP PAN
20: SLICER
63: STEP PITCH SHIFTER
The above five types contain a sixteen-step sequencer.
For these types, you can use a multi-effect control to reset the 
sequence to play from the first step.
To do this, set the multi-effect control Destination to “Step 
Reset.”
For example if you are using the modulation lever to control the 
effect, you would make the following settings.
Source:
 CC01: MODULATION
Destination:
 Step Reset
Sens:
 +63
With these settings, the sequence will play back from the first 
step whenever you operate the modulation lever.
(Double note)
(Dotted whole note),
(Dotted half note),
(Dotted thirty-second note),
(Whole note),
(Double-note triplet),
(Sixteenth-note triplet),
(Thirty-second note),
(Sixty-fourth-note triplet),
(Sixty-fourth note),
(Thirty-second-note triplet),
(Dotted eighth note),
(Quarter-note triplet),
(Eighth note),
(Half-note triplet),
(Quarter note),
(Dotted quarter note),
(Whole-note triplet),
(Half note),
(Sixteenth note),
(Eighth-note triplet),
(Dotted sixteenth note),
 
Chorus Parameters
 
Parameter
Value
Description
 
Chorus 
Type
0 (OFF), 
1 (CHORUS), 
2 (DELAY), 
3 (GM2 CHORUS)
Selects either Chorus or Delay.
0 (OFF): Neither Chorus or Delay 
is used.
1 (CHORUS): Chorus is used.
2 (DELAY): Delay is used.
3 (GM2 CHORUS): GM2 Chorus 
is used.
 
Type: 1 (CHORUS)
 
Rate
0.05–10.00 Hz, note
Frequency of modulation
Depth
0–127
Depth of modulation
Pre Delay
0.0–100.0 ms
Adjusts the delay time from the direct 
sound until the chorus sound is heard.
Feedback
0–127
Adjusts the amount of the chorus 
sound that is fed back into the effect.
Filter Type
OFF, LPF, HPF
Type of filter
OFF: no filter is used
LPF: cuts the frequency range 
above the Cutoff Freq
HPF: cuts the frequency range 
below the Cutoff Freq
Cutoff Freq
200–8000 Hz
Basic frequency of the filter
Phase
0–180˚
Spatial spread of the sound
 
Type: 2 (DELAY)
 
Delay Left
0–1000 ms, note
Adjusts the delay time from the di-
rect sound until the delay sound is 
heard.
Delay Right
Delay Center
Center 
Feedback
-98–+98 %
Adjusts the proportion of the delay 
sound that is fed back into the ef-
fect. Negative (-) settings will invert 
the phase.
HF Damp
200–8000 Hz, 
BYPASS
Adjusts the frequency above which 
sound fed back to the effect will be 
cut. If you do not want to cut the 
high frequencies, set this parameter 
to BYPASS.
Left Level
0–127
Volume of each delay sound
Right Level 
Center Level
 
Type: 3 (GM2 CHORUS)
 
Pre-LPF
0–7
Cuts the high frequency range of 
the sound coming into the chorus.
Higher values will cut more of 
the high frequencies.
Level
0–127
Volume of the chorus sound
Feedback
0–127
Adjusts the amount of the chorus 
sound that is fed back into the effect.
Delay
0–127
Adjusts the delay time from the di-
rect sound until the chorus sound is 
heard.
Rate
0–127
Frequency of modulation
Depth
0–127
Depth of modulation
Send Level 
To Reverb
0–127
Adjusts the amount of chorus sound 
that will be sent to the reverb.
(Double note)
(Dotted whole note),
(Dotted half note),
(Dotted thirty-second note),
(Whole note),
(Double-note triplet),
(Sixteenth-note triplet),
(Thirty-second note),
(Sixty-fourth-note triplet),
(Sixty-fourth note),
(Thirty-second-note triplet),
(Dotted eighth note),
(Quarter-note triplet),
(Eighth note),
(Half-note triplet),
(Quarter note),
(Dotted quarter note),
(Whole-note triplet),
(Half note),
(Sixteenth note),
(Eighth-note triplet),
(Dotted sixteenth note),
Fantom-X678_r_e.book 293 ページ 2005年5月12日 木曜日 午後4時40分