Service 
10
312350E
Service
Replacing Throat Seals 
1.
Relieve pressure, page 7.
2.
Disconnect reciprocator from pump. 
3.
Remove four capscrews (15) from bottom of adapter 
(43). Tap adapter to loosen it and pull it off the bot-
tom cap (32).
4.
Remove seal (44, included in Reciprocator Repair 
Kit 247455) from top of adapter (43).
5.
Install seal (16) in adapter (43) in the order shown in 
F
6.
Reassemble. Torque the capscrews (15) to 28-32 
ft-lb (38 to 43 N.m). Install displacement pump, see 
Step 23 on page 15.
F
IG
. 5
Use of a hydraulic power supply with fluid tempera-
tures above 154°F (68°C) can create hot surfaces 
which can burn if touched. 
Do not touch pump, motor, or if hydraulic system 
fluid is above 154°F (68°C).
Allow sufficient time for pump and motor to cool 
before attempting any service or repair.
Replace throat seals if fluid leaks excessively 
through the weep tube (B), page 4. This procedure 
can be done without disassembling entire 
reciprocator.
32
44 
8
3
35
15
19
11
Torque to 170 - 180 in-lbs (19-20 N.m)
4
ti10463a
1
1
Lips face down.
Torque to 54-56 ft-lbs (73-76 N.m).
3
4
27
10