Figure 4, stroke adjustment 
6.  Equipment Startup 
6.1 
Fastener Inspection 
All pump fasteners should be checked prior to pump operation, and occasionally during use.  This 
would include reagent head mounting bolts, motor mounting bolts, and the hardware that secures the 
pump to its foundation. Most hardware can be checked simply to ensure it is not loose.  However, utilize 
the following values when checking reagent head bolt torque: 
 
Reagent Head Bolt Torque  
Model 
Material 
# Bolts and size 
N-m 
In. - Lbs 
Plastic 
(4) M6 * 1.0 
3.39 
30 
DC2 
Metal 
(4) M6 * 1.0 
3.39 
30 
Plastic 
(4) M8 * 1.25 
6.77 
60 
DC3 and 4 
Metal 
(4) M8 * 1.25 
6.77 
60 
Plastic 
(6) M8 * 1.25 
8.46 
75 
DC5 
Metal 
(6) M8 * 1.25 
8.46 
75 
Plastic 
(6) M8 * 1.25 
8.46 
75 
DC6 
Metal 
(6) M8 * 1.25 
8.46 
75 
 
 
6.2 
Output Adjustment 
All OMNI
®
 pumps have a hand wheel for manual stroke adjustment.  The hand wheel can be adjusted to 
any point from 0 to 100%.  This value represents the stroke length setting and therefore the flow rate of 
the pump relative to its maximum output. 
 
1.  Turn the red lock screw counterclockwise to release the 
stroke lock.  Making adjustments without releasing the 
lock may damage the mechanism.
 
2.  Adjust the hand wheel to the desired output. 
a)  The stroke barrel indicates stroke length in 20% 
increments.   
b)  The hand wheel indicates stroke length in 1% 
increments.   
For example, to set the pump to 75% stroke length, 
(starting from the factory default setting of 0%) turn the 
hand wheel counter clockwise until he 60% indicator is 
visible on the stroke barrel.  
Continue the counter clockwise rotation until the hand 
wheel indicator is at 15.  Refer to Figure 4. 
3.  Turn the lock screw clockwise to lock the stroke adjustment 
into position. 
Adjustments can be made while the pump is at rest or  
operating, although adjustments are easier to make  
while the pump is in operation.