Honeywell DC3 Manual Do Utilizador

Página de 46
24 
 
 
 
 
 
 
Difficulty 
Probable Cause 
Remedy 
 
 
 
Discharge pressure too high. 
Reduce pressure. 
Water hammer. 
Install pulsation dampener. 
Stroke length at partial setting. 
Some operating noise is characteristic of 
lost motion pumps. 
Noisy gearing, 
knocking 
Low grease level. 
Add or replace grease. 
Pipe size too small. 
Increase size of piping - install pulsation 
dampener. 
Pipe runs too long. 
Install pulsation dampener in line. 
Pulsation dampener inoperative or 
flooded. 
Refill with air or inert gas. Inspect and 
replace diaphragm and recharge. 
Piping noisy. 
No surge chamber or dampener used. 
Install pulsation dampeners. 
Pump overloaded. 
Check operating conditions against pump 
design.  Verify discharge pressure 
High or low voltage. 
Check power source. 
Motor overheats. 
Loose wire. 
Trace and correct. 
 
Incorrect motor wiring 
Verify and correct