Loop Detection
17
When the module disables a front-panel port to eliminate a loop, you 
must bring the port back online manually.
Example:
CB9000@slot 5.1 [36L-E/FEN-TX-L2] (): bridge
Menu options (CoreBuilder 9000-10AD6C): 
----------------------------------------
display 
- Display bridge information 
agingTime 
- Set the bridge address aging time                 
cos 
- Administer COS priority queues 
port 
- Administer bridge ports 
multicast 
- Administer multicast filtering                    
vlan 
- Administer VLANs 
loopDetectMode  - Set Loop Detect mode 
learnMode 
- Set the bridge learning mode 
CB9000@slot 1.1 [36L-E/FEN-TX-L2] (bridge): loopdetectmode
Enter new value (disable,enable,immediate) [disable]: enable
CB9000@slot 1.1 [36L-E/FEN-TX-L2] (bridge): display
agingTime                 mode        addrTableSize
300       bridgeRepeater                  138
addressCount        peakAddrCount            learnMode
2                    4               normal
multicastLimit       broadcastLimit           floodLimit
50000                50000                50000
loopDetectMode loopDetectSrcAddress 
enable    08-00-8f-75-48-86 
CB9000@slot 1.1 [36L-E/FEN-TX-L2] (bridge/port): summary 1
rxFrames           rxDiscards             txFrames
5301100                    0              2688802
portNumber      loopDetectStatus
1          loop detect
learnStatus         addressLimit 