X600 SPECIFICATIONS
All figures obtained after 1 hour warmup, with regulated 120 VAC power line.  See manual
notes about AC power line regulation.
Gain
30 dB
Freq. Response
-0 dB at DC, -3 dB at 100 kHz
Power Output
600 watts maximum @ 1% THD, 1 kHz, 8 ohms
Distortion
refer to accompanying distortion curve
Maximum Output Voltage
plus, minus 105 volts
Maximum Output Current
plus, minus 25 amps
Input Impedance
22 kohm balanced
Damping factor
60 
ref 8 ohms nominal
Slew rate
plus, minus 50 V/uS
Output Noise
500 uV unweighted 20-20 kHz
Random noise floor
approximately 2 uV
Dynamic range
153 dB (random noise floor to peak output)
Balanced CMRR
-85 dB @ 1 kHz  (input common mode rejection ratio)
DC offset
< 100 mv
Power Consumption
600 watts idle,  1800 watts maximum
Temperature
20 degrees C. above ambient typical
Dimensions
19 " W  x  22" D  x  10.5" H
Shipping Weight
150 lbs.