Behringer 1222FX Manual Do Utilizador

Página de 15
11
XENYX 1222FX
2.3.6 Level meter and level setting
Fig. 2.14: Level meter
POWER
The blue POWER LED indicates that the device is switched
on.
+48 V
The red “+48 V” LED lights up when the phantom power supply
is  switched  on.  The  phantom  power  supply  is  necessary  for
condenser microphones and is activated using the corresponding
switch on the rear of the device.
+
Connect  microphones  before  you  switch  on  the
phantom  power  supply.  Please  do  not  connect
microphones  to  the  mixer  (or  the  stagebox/
wallbox)  while  the  phantom  power  supply  is
switched  on.  In  addition,  the  monitor/PA
loudspeakers  should  be  muted  before  you  activate
the  phantom  power  supply.  After  switching  on,
wait  approx.  one  minute  to  allow  for  system
stabilization.
LEVEL METER/CLIP
The  high-precision  level  meter  accurately  displays  the
appropriate signal level.
LEVEL SETTING:
When recording to a digital device, the recorder’s peak meter
should not exceed 0 dB. This is because, unlike analog recordings,
slightly excessive levels can create unpleasant digital distortion.
When  recording  to  an  analog  device,  the  VU  meters  of  the
recording  machine  should  reach  approx.  +3  dB  with  low-
frequency signals (e.g. kick drum). Due to their inertia VU meters
tend to display too low a signal level at frequencies above 1 kHz.
This is why, for example, a Hi-Hat should only be driven as far
as -10 dB. Snare drums should be driven to approx. 0 dB.
+
The  peak  meters  of  your  XENYX  display  the  level
virtually  independent  of  frequency.  A  recording  level
of  0  dB  is  recommended  for  all  signal  types.
2.4 Graphic 7-band equalizer
Fig. 2.15:  The  graphic  stereo  equalizer
The graphic stereo equalizer allows you to tailor the sound to
the room acoustics.
FBQ FEEDBACK DETECTION
The  switch  turns  on  the  FBQ Feedback Detection System.  It
uses  the  LEDs  in  the  frequency  band  faders  to  indicate  the
critical  frequencies. On  a  per-need  basis,  lower  the  frequency
range  in  question  somewhat  in  order  to  avoid  feedback.  The
graphic stereo equalizer has to be turned on in order to use this
function.
+
Logically,  at  least  one  (ideally  several)  microphone
channels  have  to  be  open  for  feedback  to  occur  at
all!
Feedback  is  particularly  common  when  stage  monitors
(“wedges”)  are  concerned,  because  monitors  project  sound  in
the  direction  of  microphones.  Therefore,  you  can  also  use  the
FBQ Feedback Detection for monitors by placing the equalizer in
the monitor bus (see MAIN MIX/MONITOR).
EQ IN
Use  this  switch  to  activate  the  graphic  equalizer.  When
activated, the fader LEDs will illuminate.
MAIN  MIX/MONITOR
This toggles the graphic equalizer between the main mix and the
monitor mix. With the switch up (not depressed), the equalizer is
active in stereo on the main mix, and inactive on the monitor mix.
When the switch is depressed the equalizer is active in mono
on the monitor mix, and inactive on the main mix.
2.5 Rear view of 1222FX
Fig. 2.16: Voltage supply and fuse
FUSE HOLDER/IEC MAINS RECEPTACLE
The console is connected to the mains via the cable supplied,
which  meets  the  required  safety  standards.  Blown  fuses  must
only  be  replaced  by  fuses  of  the  same  type  and  rating.  The
mains connection is made via a cable with IEC mains connector.
An appropriate mains cable is supplied with the equipment.
POWER
Use the POWER switch to power up the mixing console. The
POWER switch should always be in the “Off” position when you
are about to connect your unit to the mains.
To disconnect the unit from the mains, pull out the main cord
plug. When installing the product, ensure that the plug is easily
accessible. If mounting in a rack, ensure that the mains can be
easily disconnected by a plug pull or by an all-pole disconnect
switch on or near the rack.
+
Attention:  The  POWER  switch  does  not  fully
disconnect  the  unit  from  the  mains.  Unplug  the
power  cord  completely  when  the  unit  is  not  used
for  prolonged  periods  of  time.
PHANTOM
The  PHANTOM  switch  activates  the  phantom  power  supply
for  the  XLR  microphone  inputs,  which  is  required  to  operate
condenser  microphones.  The  red  +48  V  LED  lights  up  when
phantom power is on. As a rule, dynamic microphones can still
be  used  with  phantom  power  switched  on,  provided  that  they
are wired in a balanced configuration. In case of doubt, contact
the microphone manufacturer!
2. CONTROL ELEMENTS AND CONNECTORS