Turbosound TA-500DP Manual Do Utilizador

Página de 73
user manual 
TA-500 
TA-500 user manual 
Page 66 
of performance may be experienced if connected to unbalanced sources. If it is unavoidable, 
however, the following wiring convention should be used. 
 
Pin 1 
Screen - connect to chassis of the unbalanced equipment, 
or left disconnected at the unbalanced end 
Pin 2 
signal hot 
Pin 3 
Signal cold 
 
 
Polarity 
In accordance with international standards, T series amplifiers are supplied with Pin 2 hot (+), 
so a positive (+V) input gives a positive (+V) output from the positive (+) output terminals. 
 
Input Impedance 
Each amplifier channel has an input impedance of 10kΩ, seen between pins 2 & 3 of the XLR. 
When used with the LMS-D6 Loudspeaker Management System, distribution amplifiers are 
not required when a large number of T-25 or T-45 amplifier inputs are driven in parallel. 
 
Gain and Sensitivity Settings 
Gain settings are changed internally by simple jumper links. Two rows of pins marked - GAIN 
A and GAIN B - are situated on the input PCB (PCB701). A jumper link sets the gain and the 
settings are as follows: 
 
 
 
Link 1 & 2 
Gives 32dB gain 
Link 3 & 4 
Gives 26dB gain 
Link 2 & 3 
Gives approx 37.5dB gain 
 
NOTE: Factory setting is normally link 1 & 2 = 32dB gain.