Renesas SH7709S Manual Do Utilizador

Página de 807
Rev. 5.00, 09/03, page 666 of 760
V
CC
 min
t
RESPW
t
RESPS
t
OSC1
V
CC
RESETP
CKIO,
internal clock
Stable oscillation
Note: Oscillation settling time when built-in oscillator is used
Figure 23.4   Power-on Oscillation Settling Time
CKIO,
internal
clock
Stable oscillation
Standby
t
OSC2
t
RESPW/MW
t
RESPS/MS
RESETP
RESETM
Note:  Oscillation settling time when built-in oscillator is used in the oscillation off mode
Figure 23.5   Oscillation Settling Time at Standby Return (Return by Reset)