Mitsubishi Electronics MR-J2-03A5 Manual Do Utilizador
6 - 7
6. DISPLAY AND OPERATION
(b) 5-digit parameter
The following example shows the operation procedure performed to change the electronic gear
denominator (parameter No. 4) into "12345":
denominator (parameter No. 4) into "12345":
Call the display screen shown after power-on.
Press MODE once. Select parameter No. 4 with UP / DOWN.
Press SET once.
Press MODE once.
Fifth digit setting
Press SET once.
The screen flickers.
⋅⋅⋅⋅⋅⋅
⋅⋅⋅⋅⋅⋅
Change the set value
with UP / DOWN.
Press SET once.
The set value is enterd.
⋅⋅⋅
⋅⋅⋅
Press UP or DOWN.
To the next parameter
Lower 4 digits setting
Press SET once.
(2) Expansion parameters
To use the expansion parameters, change the setting of parameter No. 19 (parameter write disable).
Refer to section 5.1.1.
Refer to section 5.1.1.