Configuring the Sensor I/O Port — Sensor I/O Setting Page
27
Inter-alarm Event Detection Time
Type the duration, between 5 and 60 seconds, during 
which the camera can detect the next alarm input.
Showing Pop-up
You can set for displaying  “SI” (Sensor Input) pop-up 
on the lower-right of the monitor image when an alarm 
output is detected.
Select On to show a pop-up, or Off not to show it.
Notes
• To show the pop-up on the Firewall Viewer, check on 
Show in the Caption menu when you are using the 
Firewall Viewer. (See “Caption” on page 10.)
• The pop-up is not displayed when the Java Applet 
Viewer is used.
Output 2
Set up Output 2 of the Sensor I/O port.
Output 2 can output an alarm triggered by the sensor 
input or manually.
Output Status Control
Select Active to keep Output 2 of the Sensor I/O port 
usually open and short-circuit it only when an alarm is 
output.  Select De-Active to keep Output 2 usually 
short-circuited and open it only when an alarm is ouput.
Alarm Event-Based Output Activation Function
Select SI to synchronize the output from Output 2 of the 
Sensor I/O port with an alarm by the sensor input, or 
Manual to output manually by clicking the Sensor 2 
button on the viewer page. 
Output Active Duration Time
Type the duration of the output from Output 2 between 
1 and 60 seconds.
Apply/Cancel/Help