Configuration with the CCIC1410 Homepage 
75 
Siemens Building Technologies
 
 
Fire Safety & Security Products 
 
05.2009
 
 
Event settings 
In the Event settings section, click Add to open the event setting page. 
In this page, you can arrange the three elements – Trigger, Schedule and Action – 
to configure an event. A total of three event settings can be configured. 
 
z
 
Event name: 
Enter a descriptive name for the event. 
– 
Enable this event: 
Select this option to enable this event. 
– 
Priority: 
Select the relative importance of this event (High, Normal, and Low). Events with 
higher priority setting will be executed first. 
– 
Detect next after …… second(s): 
Enter the duration in seconds for which motion detection is to be paused after a 
motion has been detected. 
 
An event is an action initiated by a user-defined trigger source; it is the causal 
arrangement of the following three elements: 
Î
 
Trigger 
Î
 
Event Schedule 
Î
 
Action