1.  Remove the dome by twisting counterclockwise.  Be 
careful not to scratch the dome.  Do not touch any of 
the components inside the dome. 
2.  Temporarily connect the camera to the video monitor via 
the video cable.  If a service monitor is available, use the 
included service monitor adapter. 
3.  Temporarily connect the camera to a 12VDC  
power source.  (24VAC may be connected for  
EV-2660-NKBAQ and EV-2661-NKBQ). 
4.  Hold the base of the dome camera with your hand against 
the ceiling, and try various locations and angles while 
watching the video monitor to find the location which 
offers the best protection.  Mark that location  
with a pencil. 
5.  Run a hidden, permanent video cable from the monitor to 
the mounting location. 
 
Before Starting 
Installation 
1.  This product was designed for indoor use only.  Do not 
mount the CCTV camera where it is exposed to rain or 
other moisture, or in humid or dusty places. 
2.  Do not point the CCTV camera at the sun.  Heat could 
damage the camera, even when not in use. 
3.  Do not mount the CCTV camera in areas exposed to 
radiation, strong magnetic fields, or strong electrical 
signals.* 
4.  Do not open or disassemble the camera.  There are no 
user serviceable parts inside. 
5.  Do not drop the camera or subject it to strong vibrations. 
 
 
Note: Many video monitors produce strong 
electromagnetic fields close to the display CRT, 
especially when the monitor is turned on or during de-
Gaussing, which occurs automatically with many 
monitors when the monitor is turned on. 
Installation 
6.  Run a hidden cable from the power supply to the 
mounting location. 
7.  Connect the two cables to the dome camera.  Do not 
cut any wires, as warranty will be voided.  If needed, 
use the included DC plug with terminal block. 
8.  Mount the base to the ceiling at the selected location. 
9.  Use the 3-axis gimbal to adjust the angle of the camera. 
(See opposite page for further instructions.) 
10. Make any necessary adjustments to the Zoom and 
Focus by pulling the respective levers out and turning 
them clockwise or counterclockwise. 
11. Replace the dome, taking care not to touch the camera 
or scratch the dome. 
12. Test the camera again under the exact lighting 
conditions under which it is expected to be used. 
DC plug with terminal block 
Mounting screw 
Focus 
Zoom 
Dome 
Base 
EV-2660-NKBQ or EV-2660-NKBAQ shown.  Installation is the same for all three models. 
DC Jack 
(connect to power) 
Female BNC connector 
(connect to video device) 
Service monitor adapter 
Connect to service monitor 
at the installation site 
Important: Do not cut DC jack or BNC connector as 
warranty will be voided.
 
Service Monitor Port 
Connects to Service 
Monitor Port 
Mounting surface