Sanyo VCC-MD500P Manual Do Utilizador

Página de 42
− 16 −
Message
Backlight BLC OFF
A0 06 00 CS FF  
 
 
 
Backlight compensation OFF
Multi BLC ON
A0 06 01 CS FF  
 
 
 
Backlight compensation multifractionated evaluative metering mode (Backlight compensates after 
measuring the light of the entire screen.) 
  Multi BLC Weight -
A0 06 04 00 CS FF  
 
 
Sensitivity settings during Multi BLC
BLC is easier to determine with a larger value (Initial value: 7)
  Multi BLC Weight +
A0 06 04 01 CS FF  
 
 
  Multi BLC Weight Preset
A0 06 05 CS FF  
 
 
 
Returns sensitivity during Multi BLC to factory defaults (Initial value: 7)
  Multi BLC Weight Direct
A0 06 06 0p CS FF  
 
 
p: Direct sensitivity settings 0-15 during Multi BLC (Initial value: 7)
  Multi BLC Bright -
A0 06 07 00 CS FF  
 
 
Brightness settings during Multi BLC
Larger value increases brightness when determining BLC (Initial value: 7)
  Multi BLC Bright +
A0 06 07 01 CS FF  
 
 
  Multi BLC Bright Preset
A0 06 08 CS FF  
 
 
 
Returns brightness settings during Multi BLC to factory defaults (Initial value: 7)
  Multi BLC Bright Direct
A0 06 09 0p CS FF  
 
 
p: Direct brightness settings 0-15 during Multi BLC (Initial value: 7)
Center BLC ON
A0 06 0B CS FF  
 
 
 
BLC center-weighted metering mode (Backlight compensates after measuring the light mainly in the 
center.)
  Center BLC Weight Preset
A0 06 0F CS FF  
 
 
 
Returns sensitivity settings during Center BLC to factory defaults (Each initial value: 0) 
  Center BLC Weight Direct
A0 06 10 0p 0q 0r 0s CS FF Sensitivity settings during Center BLC 
p: Top(0-7)  q: Bottom(0-7)  r: Left(0-7)  s: Right(0-7) (Each initial value: 0)
  Center BLC Area Preset
A0 06 12 CS FF  
 
 
 
Returns center area settings during Center BLC to factory defaults (Each initial value: 0)
  Center BLC Area Direct
A0 06 13 0p 0q 0r 0s CS FF Center area settings during Center BLC 
p: x-position(0-7)  q: y-position(0-5) r: x-size(0-7)  s: y-size(0-5) 
(Initial value: x-position: 2 y-position: 1 x-size: 3 y-size: 3)
*When x-size:0 y-size:0, it becomes 1 area.
Mask BLC ON
A0 06 15 CS FF  
 
 
 
BLC mask mode
  Mask BLC Area Preset
A0 06 19 CS FF  
 
 
 
Return mask area settings during Mask BLC to factory defaults
  Mask BLC Area Direct
A0 06 1D 0p 0q 0r 0s 0t 0u Mask area settings during Mask BLC  
(Note 1)
  0v 0w 0x 0y 0z 0n CS FF
BLC ON
A0 06 33 CS FF  
 
 
 
Returns to the mode before BLC OFF only when BLC OFF
Shutter 
Speed
Shutter Speed +
A0 07 0B CS FF  
 
 
 
Increases shutter speed by one notch
Shutter Speed -
A0 07 0C CS FF  
 
 
 
Decreases shutter speed by one notch
Shutter Speed Set long
A0 07 0E 0p CS FF  
 
 
Shutter Speed Mode Settings
0: Prolonged exposure shutter mode, 1: Normal mode, 3: High speed shutter mode
Shutter Speed OFF 
A0 07 0F CS FF  
 
 
 
Same as Shutter Speed Set OFF
Shutter Long Direct
A0 07 11 0p CS FF  
 
 
Shutter speed settings during prolonged exposure shutter mode 
(0: x1, 1: x2, 2: x4, 3: x8, 4: x16, 5: x32)
Shutter Short Direct
A0 07 12 0p CS FF  
 
 
Shutter speed settings during high speed shutter mode 
(0: 1/60 (50), 1:1/100 (120), 2: 1/250, 3: 1/500, 4: 1/1000, 5: 1/2000, 6: 1/4000, 7: 1/10000)
Sense Up +       
A0 07 1A CS FF
Increase electronic sensitivity settings
Sense Up -         
A0 07 1B CS FF
Sense Up Direct
A0 07 1D 0p CS FF
p: Direct increased electronic sensitivity settings 
(0: OFF, 1: x2, 2: x4, 3: x8, 4: x16, 5: x32)
ELS OFF           
A0 07 28 CS FF  
 
 
 
Sets shutter speed to 1x (1/60) after saving
ELS ON            
A0 07 29 CS FF  
 
 
 
Returns to electronic shutter speed saved by ELS OFF
Motion 
Detector
Motion Detector OFF
A0 08 00 CS FF  
 
 
 
Motion sensor ON/OFF
Motion Detector ON
A0 08 01 CS FF  
 
 
 
Motion Size Preset
A0 08 05 CS FF  
 
 
 
Returns detected motion size settings to factory defaults (Initial value: V-Size: 1, H-Size: 1)
Motion Size Direct
A0 08 06 0p 0q CS FF  
 
Detected motion size settings  p: V-Size (1-6)  q: H-Size (1-8) (Initial value: V-Size: 1, H-Size: 1)
Alarm Sign OFF
A0 08 08 CS FF
Display ON/OFF during alarm input
Alarm Sign ON
A0 08 09 CS FF
Masking OFF
A0 08 0A CS FF  
 
 
 
Mask area settings for motion detection ON/OFF
Masking ON
A0 08 0B CS FF  
 
 
 
Mask Area Preset 
A0 08 0F CS FF  
 
 
 
Returns mask area for motion detection to factory defaults
Mask Area Direct
A0 08 13 0p 0q 0r 0s 0t 0u Mask area settings for motion detection  
(Note 1)
  0v 0w 0x 0y 0z 0n CS FF
Sensitivity Move +
A0 08 15 CS FF  
 
 
 
Motion detection sensitivity settings (Initial value: 5)
Sensitivity Move -
A0 08 16 CS FF  
 
 
 
Sensitivity Move Preset
A0 08 19 CS FF  
 
 
 
Returns motion detection sensitivity settings to factory defaults (Initial value: 5)
Sensitivity Move Direct
A0 08 1D 0p CS FF  
 
 
p: Direct motion detection sensitivity settings 1-10 (Initial value: 5)
Sensitivity Y-Level +
A0 08 1F CS FF  
 
 
 
Minimum brightness settings for motion detection (Initial value: 5)
Sensitivity Y-Level -
A0 08 20 CS FF  
 
 
 
Sensitivity Y-Level Peset
A0 08 23 CS FF  
 
 
 
Returns minimum brightness settings for motion detection to factory default (Initial value: 5)
Sensitivity Y-Level Direct
A0 08 27 0p CS FF  
 
 
p: Direct minimum brightness settings for motion detection 1-10 (Initial value: 5)
Sensitivity Y-Differ +
A0 08 29 CS FF  
 
 
 
Brightness variation settings for undetected motion (Initial value: 5)
Sensitivity Y-Differ -
A0 08 2A CS FF  
 
 
 
Sensitivity Y-Differ Preset
A0 08 2D CS FF  
 
 
 
Returns brightness variation settings for undetected motion to factory defaults (Initial value: 5)
Sensitivity Y-Differ Direct
A0 08 31 0p CS FF  
 
 
p: Direct brightness variation settings for undetected motion 1-10 (Initial value: 5)
Sensitivity Duration +
A0 08 33 CS FF  
 
 
 
Continuous movement time for motion detection (Initial value: 1)
Sensitivity Duration -
A0 08 34 CS FF  
 
 
 
Sensitivity Duration Preset
A0 08 37 CS FF  
 
 
 
Returns continuous movement time for motion detection to factory defaults (Initial value: 1)
Sensitivity Duration Direct
A0 08 3B 0p CS FF  
 
 
p: Direct continuous movement time for motion detection 1-60 (Initial value: 1)
Motion Zoom
A0 08 3D 0p CS FF  
 
 
p: Zoom magnification during motion detection 
(0: OFF, 1: x1.4, 2: x2, 3: x2.8, 4: x4, 5: x6)
Motion Interval
A0 08 42 0p CS FF  
 
 
p: Interval time until the start of next detection during motion detection 
(0: 5s, 1: 10s, 2: 15s, 3: 20s, 4: 30s, 5: 1m, 6: 2m, 7: 3m, 8: 4m, 9: 5m)
Sync
Sync INT
A0 09 00 CS FF  
 
 
 
Internal synchronization mode
Sync L-L
A0 09 01 CS FF  
 
 
 
Power supply synchronization mode
L-L Phase +
A0 09 0B CS FF  
 
 
 
Synchronous phase settings for power source synchronization
L-L Phase -
A0 09 0C CS FF  
 
 
 
L-L Phase Preset
A0 09 0F CS FF  
 
 
 
Returns synchronous phase settings for power source synchronization to factory defaults  
(Initial value: 0)
L-L Phase Direct
A0 09 13 0p 0q 0r CS FF  
pqr: Synchronous phase settings for power source synchronization 
Direct 0-524 (NTSC) / 0-624 (PAL) (Each initial value: 0)
 
*1: Only MD400  CS: Checksum
 
*2: Only MD300  FF: Terminator
Communications Protocol