IBM 21Y Manual Do Utilizador

Página de 210
132
Netfinity 3500-M20 – Type 8657 Models 21Y, 22Y, 31Y, 32Y,
3-2-3
(Math 
coprocessor 
failed)
1. Optional processor (if 
installed)
2. Processor
3. System board
3-2-4
(Failure 
comparing 
CMOS memory 
size against 
actual)
1. DIMM
2. Battery
3. System board
3-3-1
(Memory size 
mismatch 
occurred, see 
"Memory 
Settings" on 
page 36)
1. DIMM
2. System board
3. Battery
3-3-2
(Critical SMBUS 
error occurred) 
(I2C bus error)
1. Disconnect the server power 
cord from outlet, wait 30 
seconds and retry.
2. System Board
3. DIMMs
4. Power Supply
5. 12C Cable
3-3-3                             
(No operational 
memory in 
system)
1. Install or reseat the memory 
modules, then do a 3 boot 
reset. 
 (See “Using the 
Configuration/Setup Utility 
program” on page 33
.)
2. DIMMs
3. System Board
Two Short 
Beeps 
(Information 
only, the 
configuration 
has changed)
1. Run Diagnostics
2. Run Configuration/Setup
Three Short 
Beeps
1. DIMM
2. System Board
One 
Continuous 
Beep
1. Processor
2. Optional Processor  (if installed)
3. System Board
Repeating 
Short Beeps
1. Keyboard
2. System Board
One Long and 
One Short Beep
1. Video adapter (if present)
2. System Board
Beep/Symptom
FRU/Action