NDIS 4.0 (Windows NT) driver messages
This section contains the error messages for the NDIS 4.0 
drivers.  The explanation and recommended action are 
included with each message.
PCNTND-25
PCI scan specified, PCI bus not found!  
Explanation:  The driver cannot locate 
the PCI bus.  
Action:  Run the diagnostic programs.
PCNTND-29
WARNING:  DMA number is not 
necessary for PCI device.  
 
Explanation:  The Ethernet controller 
does not require a DMA setting.
Action:  Remove the DMA setting in the 
PROTOCOL.INI file.
PCNTND-33
PCNET device with specified IOBASE 
is already in use.  
 
Explanation:  The specified I/O address 
number is already in use by another 
Ethernet controller or device.  
Action:  Remove the I/O address setting 
in the PROTOCOL.INI file.
Table 4. NDIS (Windows NT) driver messages for the 
Ethernet controller 
PermaNet 
Server:
No Secondary Adapter Found.  
Grouping Mode is disabled.  
 
Explanation:  The failover option requires 
an adapter that is compatible with the 
device driver of the Ethernet controller on 
the system board.  No such adapter was 
found.   
Action:  
Make sure the correct adapter is 
installed.       
PermaNet 
Server:  
Problem Occurs on the Primary 
Adapter.  Switching over to the 
Secondary Adapter.  
 
Explanation:  The system detected a 
problem with the primary Ethernet 
connection and has transferred all network 
traffic to the secondary Ethernet controller.   
Action:  
identify the cause of the failure 
on the primary Ethernet connection.  
Restoring the operational state of the 
primary connection will cause the network 
traffic to automatically transfer to the 
primary Ethernet controller.