Toshiba IK-TF5U Manual Do Utilizador

Página de 36
26
About 1 
µ
s
Exposure completion
0 to 1H*
3
Exposure period*
2
Trigger*
1
Negative polarity mode
Positive polarity mode
(Internal VD)
RGB data 
(video interval image)
FVAL
LVAL, 
DVAL
20H (Partial scanning OFF)
14H (Partial scanning 90fps)
18H (Partial scanning 115fps)
18H (Partial scanning 120fps)
22H (Partial scanning 160fps)
23H (Partial scanning 180fps)
26H (Partial scanning 240fps)
( 2 )   1P SR (1 Pulse Trigger Sync Reset)
Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, the vertical sync signal is
reset and frame images are output.
(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing
*1: Externally input signal
*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".
*3: VD is generated after 0 to 1H following the completion of the exposure period and the video is synchro-
nized to this and output.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig-
ger, there will be an effect on the video.