Toshiba Toshiba Manual Do Utilizador

Página de 149
  TOSHIBA Network Camera - IK-WB15A -      SDK (Ver 1.00.SC) 
 
©TOSHIBA Corp. 
31 
From the last page. 
Item 
Type 
Entry name 
Entry value 
Std.val 
Unit 
Bottom limit 
Mode
1:OFF
  2:ON
1
-
Bottom limit position 
type=BottomLimitSetting 
Degree
0  - 1200
0
-
Log output control of cgi common to all types
OpeLog
No/Yes [default: Yes] (omissible)
-
-
 
2.1.3 Output 
Code 
Status 
Code
Status
Code
Status
20 OK 
32
InvalidValue
92
CriticalError
30 InvalidType 
33
InvalidOperand
31 InvalidEntry 34
NoEntryData
 
2.1.4 Example 
1) http://10.1.0.1/api/wbsetptbasic.cgi?type=Default 
2) http://10.1.0.1/api/wbsetptbasic.cgi?type=PTCondition&ScanSpeed=2&PowerUp=4&FreezeActivity=2 
3) http://10.1.0.1/api/wbsetptbasic.cgi?type=AssociationToAlarm&Mode=2&PTByMotion=2&PresetNumber=33&Resume=1 
4) http://10.1.0.1/api/wbsetptbasic.cgi?type=LeftLimitSetting&Mode=2&Degree=175 
5) http://10.1.0.1/api/wbsetptbasic.cgi?type=RightLimitSetting&Mode=1 
6) http://10.1.0.1/api/wbsetptbasic.cgi?type=TopLimitSetting&Mode=2&Degree=175 
7) http://10.1.0.1/api/wbsetptbasic.cgi?type=BottomLimitSetting&Mode=1 
 
2.1.5 Notes 
1)  If only type=Set is entered and then <entry>=<value> is not entered, no setting is performed. (type=Default is an exception.) 
2) Multiple 
type=<value> cannot be enumerated simultaneously. This API must be started for each type. 
3)  For only entered items, setting is performed. For the other items, their existing values are held. 
4)  When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes. 
5)  Setting values of “Degree” is defined in Appendix.C