Lucent Technologies Release 7 Manual Do Utilizador

Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-539
DIOD-TRK (DIOD Trunk) 
9
PASS
This test passed. Translation information was successfully updated on the 
circuit pack. User-reported troubles on this port should be investigated by 
using other port tests and by examining trunk or external wiring. If the trunk is 
busied out, the test does not run, but returns PASS. To verify that the trunk is 
in-service:
1. Enter status-command to verify that the trunk is in-service. If the trunk is 
in-service, no further action is necessary. If the trunk is out-of-service, 
continue to Step 2.
2. Enter release-trunk command to put trunk back into in-service.
3. Retry the test command.
Table 9-222.
TEST #36 Port Audit Update Test  — Continued
Error 
Code
Test 
Result
Description/ Recommendation
Continued on next page