Lucent Technologies Release 7 Manual Do Utilizador

Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-909
HYB-LINE (Hybrid Line) 
9
length of the wiring between the terminal and the switch). If the problem 
persists, replace the circuit pack. Once the problem has been resolved, 
the alarm will be retired after a predetermined delay.
b. Error type 18 indicates the port is busied out. The port is released with 
release port UUCSSpp.
c. The circuit pack has been removed or has been insane for more than 11 
minutes. To clear the error, reinsert or replace the circuit pack.
d. The EPF has been turned off due to an overcurrent condition at the voice 
terminal. Check for defective wiring or a damaged jack, and make sure 
the voice terminal is a Hybrid set. Once the problem has been resolved, 
the alarm will be retired after a predetermined delay.
e. The voice terminal has been disconnected or there is a problem in the 
wiring to the terminal. Make sure that the voice terminal is connected or 
check for defective wiring to the voice terminal.
f. Note that Error Types 769 and 1281 by themselves create Warning alarms 
only, but if both are present, a Minor alarm will be logged.
g. The port has reported a problem with the data link to the voice terminal. 
Ignore this error if there are no complaints about the voice terminal. 
Otherwise, make sure the voice terminal is connected, check for defective 
wiring, check for a defective voice terminal, and decrease the length of 
the wiring between the voice terminal and the switch. If the problem 
persists, replace the circuit pack.
h. The voice terminal went off-hook while in the disconnect state. Use the 
status station command to determine the state of the terminal. The 
off-hook should have moved the terminal to in-service. No repair action is 
necessary.
i. The link between the circuit pack and the voice terminal has been 
successfully reset. No repair action is necessary.
j. Error 15 indicates a software audit error that does not indicate any 
hardware malfunction. Run the short test sequence and investigate any 
errors.