9-1528
STO-DATA (Stored Data) 
9
1347
ABORT
Could not run the test on the Standby SPE
Refresh not complete. 
1. When the standby SPE is restored to service (use status spe to determine 
state of standby SPE) retry the command. 
1350
ABORT
Could not run the test on the Standby SPE
Shadowing not enabled.
1. When the standby is restored to service (use status spe to determine 
state of standby) retry the command.
2000
ABORT
Response to the test request was not received within the allowable time 
period. 
1. Retry the command at 1-minute intervals for a maximum of 5 retries. 
2500
ABORT
Could not run the test on the Standby SPE
Internal software error. 
1. Retry the command at 1-minute intervals a maximum of 5 retries. 
30004
FAIL
The tape could not be read. 
1. Verify a tape cartridge is in the tape drive. 
2. Retry the command at 1-minute intervals for a maximum of 5 retries.
30014
FAIL
An invalid file system was found.
1. Verify the correct tape cartridge is in the tape drive. 
2. Otherwise, insert the correct tape cartridge and re-run test stored-data 
long
30201
FAIL
The checksums of the boot images for the tape are inconsistent. 
1. If a tape-only system, replace the tape. Follow the procedures presented 
in the Section XXX of this manual.
2. If a disk/tape system, run backup disk full on the carrier containing the 
bad tape (this could take up to an hour to complete).
3. Run test stored-data long to resolve the alarms.
PASS
The checksums are consistent between the two boot images on the tape. 
1. If other mss errors are present, refer to the maintenance information for the 
HOST ADAPTER, TAPE, and DISK maintenance objects to clear those 
errors.
Table 9-579.
TESTS #829 and #830 Tape Checksum Tests  — Continued
Error 
Code
Test 
Result
Description/ Recommendation