Lucent Technologies Release 7 Manual Do Utilizador

Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Additional Maintenance Procedures 
6-6
Software updates 
6
Table 6-1.
Software Update
Simplex SPE 
Step
Time 
(min)
Remarks
change sys-par 
maint
2
Note the current settings of the Save Translation and Alarm 
Origination Activated fields and then set them to n. Set CPE 
Alarm Activation Level to 
none
. Make sure scheduled daily 
maintenance is not set to run during the update.
save 
announcements
40
These steps create a backup tape in case the update fails 
and a backout is necessary. Saving announcements may be 
skipped if display announcements shows no administered 
announcements.
save translation
2
backup disk
10
Remove the 
backup tape and 
clean the tape 
drive
5
This procedure is described under 
 in 
Chapter 9, 
‘‘Maintenance Object Repair Procedures’’
.
Insert the tape with 
the new software
2
Wait for the tape to retension itself.
list config 
software-version
5
Make sure the tape has the expected version number.
restore disk 
install
10
This copies files from the new tape to disk. If you are 
updating 
from a load earlier than 6.0, substitute for this step 
the following sequence: copy announce tape, save 
translation tape
, then restore disk full.
The following step will result in the service effects described above.
upgrade software 
to-version
10
Use the new software version number described above. The 
system will reboot and then reload translations. Results of 
each step in the upgrade process and initialization 
diagnostics will be displayed on the terminal. A full 
description of screen output appears in upgrade software 
in 
Chapter 8, ‘‘Maintenance Commands’’
.
NOTE:
Be careful not to touch the G3-MT keyboard while 
waiting for the command to execute, or the result 
messages may be lost.
Login on the G3-MT.
Continued on next page