Lucent Technologies Release 7 Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Additional Maintenance Procedures
6-6
Software updates
6
Table 6-1.
Software Update
—
Simplex SPE
Step
Time
(min)
Remarks
change sys-par
maint
maint
2
Note the current settings of the Save Translation and Alarm
Origination Activated fields and then set them to n. Set CPE
Alarm Activation Level to
Origination Activated fields and then set them to n. Set CPE
Alarm Activation Level to
none
. Make sure scheduled daily
maintenance is not set to run during the update.
save
announcements
announcements
40
These steps create a backup tape in case the update fails
and a backout is necessary. Saving announcements may be
skipped if display announcements shows no administered
announcements.
and a backout is necessary. Saving announcements may be
skipped if display announcements shows no administered
announcements.
save translation
2
backup disk
10
Remove the
backup tape and
clean the tape
drive
backup tape and
clean the tape
drive
5
This procedure is described under
Chapter 9,
‘‘Maintenance Object Repair Procedures’’
.
Insert the tape with
the new software
the new software
2
Wait for the tape to retension itself.
list config
software-version
software-version
5
Make sure the tape has the expected version number.
restore disk
install
install
10
This copies files from the new tape to disk. If you are
updating
updating
from a load earlier than 6.0, substitute for this step
the following sequence: copy announce tape, save
translation tape, then restore disk full.
translation tape, then restore disk full.
The following step will result in the service effects described above.
upgrade software
to-version
to-version
10
Use the new software version number described above. The
system will reboot and then reload translations. Results of
each step in the upgrade process and initialization
diagnostics will be displayed on the terminal. A full
description of screen output appears in upgrade software
in
system will reboot and then reload translations. Results of
each step in the upgrade process and initialization
diagnostics will be displayed on the terminal. A full
description of screen output appears in upgrade software
in
Chapter 8, ‘‘Maintenance Commands’’
.
NOTE:
Be careful not to touch the G3-MT keyboard while
waiting for the command to execute, or the result
messages may be lost.
waiting for the command to execute, or the result
messages may be lost.
Login on the G3-MT.
Continued on next page